Objectives:The aim of the present study was to assess the relationship between the maxillary sinus floor and the maxillary posterior teeth root tips using dental cone-beam CT.Methods:A total of 87 right and 89 left maxillary sinus regions from 92 patients were examined using dental cone-beam CT. Images were analyzed by a specialist in oral and maxillofacial radiology. Perpendicular lines were drawn on the cross-sectional images between the deepest point of the maxillary sinus floor and the root tips of the maxillary first and second premolars and first, second and third molars, and the distances were measured using built-in measurement tools. Means, standard deviations and minimum and maximum values were calculated for all right and left premolars and molars. T-tests were used to compare measurements between left and right sides and between female and male patients.Results:The distance between sinus floor and root tip was longest for the first premolar root tip and shortest for the second molar buccodistal root tip for both right and left sides. No statistically significant differences were found between the right and left side measurements or between female and male patients (P>.05).Conclusions:Knowledge of the anatomical relationship between the maxillary sinus floor and the maxillary posterior teeth root tips is important for the preoperative treatment planning of maxillary posterior teeth.
Buccal peri-implant defects were more difficult to detect than buccal periodontal defects. No difference was found among CBCT images obtained with and without AR modes.
Objective: The purpose of this study was to assess the in vitro diagnostic ability of visual inspection, film, charge-coupled device (CCD) sensor, photostimulable phosphor (PSP) sensor and cone beam CT in the detection of proximal caries in posterior teeth compared with the histological gold standard. Methods: Visual inspection, film, CCD, PSP and cone beam CT images were used to detect proximal caries in the mesial and distal surfaces of 138 teeth (276 surfaces). Visual inspection and evaluation of all intraoral digital and conventional radiographs and cone beam CT images were performed twice by three oral radiologists. Weighted kappa coefficients were calculated to assess intra-and interobserver agreement for each image set, and scores were compared with the histological gold standard using receiver operating characteristic (ROC) analysis to evaluate diagnostic ability. Results: Intraobserver kappa coefficients calculated for each observer for each method of detecting caries ranged from 0.739 to 0.928. Strong interobserver agreement ranging from 0.631 to 0.811 was found for all detection methods. The highest Az values for all three observers were obtained with the cone beam CT images; however, differences between detection methods were not statistically significant (P . 0.05). Conclusion: Visual inspection, film, CCD, PSP plates and cone beam CT performed similarly in the detection of proximal caries.
Objectives: To investigate the reliability and accuracy of cone beam CT (CBCT) images obtained at different fields of view in detecting and quantifying simulated buccal marginal alveolar peri-implant defects. Methods: Simulated buccal defects were prepared in 69 implants inserted into cadaver mandibles. CBCT images at three different fields of view were acquired: 40 3 40, 60 3 60 and 100 3 100 mm. The presence or absence of defects was assessed on three sets of images using a five-point scale by three observers. Observers also measured the depth, width and volume of defects on CBCT images, which were compared with physical measurements. The kappa value was calculated to assess intra-and interobserver agreement. Six-way repeated analysis of variance was used to evaluate treatment effects on the diagnosis. Pairwise comparisons of median truepositive and true-negative rates were calculated by the x 2 test. Pearson's correlation coefficient was used to determine the relationship between measurements. Significance level was set as p , 0.05. Results: All observers had excellent intra-observer agreement. Defect status (p , 0.001) and defect size ( p , 0.001) factors were statistically significant. Pairwise interactions were found between defect status and defect size (p 5 0.001). No differences between median true-positive or true-negative values were found between CBCT field of views (p . 0.05). Significant correlations were found between physical and CBCT measurements (p , 0.001). Conclusions: All CBCT images performed similarly for the detection of simulated buccal marginal alveolar peri-implant defects. Depth, width and volume measurements of the defects from various CBCT images correlated highly with physical measurements.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.