We report an ultrasound contrast agent for which we engineered the shell structure to impart much better stability under intense stress and deformation.
Colloidal suspensions containing microscopic swimmers have been the focus of recent studies aimed at understanding the principles of energy transfer in fluidic media at low Reynolds number conditions. Going down in scale, active enzymes have been shown to be force-generating, nonequilibrium systems, thus offering opportunity to examine energy transfer at the ultralow Reynolds number regime. By monitoring the change of diffusion of inert tracers dispersed in active enzyme solutions, we demonstrate that the nature of energy transfer in these systems is similar to that reported for larger microscopic active systems, despite the large differences in scale, modes of energy transduction, and propulsion. Additionally, even an enzyme that catalyzes an endothermic reaction behaves analogously, suggesting that heat generation is not the primary factor for the observed enhanced tracer diffusion. Our results provide new insights into the mechanism of energy transfer at the molecular level.
In situ forming implants (ISFIs) have shown promise as a sustained, local drug delivery system for therapeutics in a variety of applications. However, development of ISFIs has been hindered by poor correlation between in vitro study results and in vivo performance. In contrast to oral dosage forms, there is currently no clear consensus on a standard for in vitro drug dissolution studies for parenteral formulations. Recent studies have suggested that the disparity between in vivo and in vitro behavior of phase-inverting ISFIs may be, in part, due to differences in injection site stiffness. Accordingly, this study aimed to create acrylamide-based hydrogel phantoms of various porosities and stiffness, which we hypothesized would better predict in vivo performance. Implant microstructure and shape were found to be dependent on the stiffness of the phantoms, while drug release was found to be dependent on both phantom porosity and stiffness. Specifically, SEM analysis revealed that implant porosity and interconnectivity decreased with increasing phantom stiffness and better mimicked the microstructure seen in vivo. Burst release of drug increased from 31% to 43% when in standard acrylamide phantoms vs macroporous phantoms (10 kPa), improving the correlation to the burst release seen in vivo. Implants in 30 kPa macroporous phantoms had the best correlation with in vivo burst release, significantly improving (p < 0.05) the burst release relative to in vivo from 64%, using a standard PBS dissolution method, to 92%. These findings confirm that implant behavior is affected by injection site stiffness. Importantly, with appropriate optimization and validation, hydrogel phantoms such as the one investigated here could be used to improve the in vitro-in vivo correlation of in situ forming implant formulations and potentially augment their advancement to clinical use.
One of the challenges in developing sustained-release local drug delivery systems is the limited treatment volume that can be achieved. In this work, we examine the effectiveness of using low frequency, high intensity ultrasound to promote the spatial penetration of drug molecules away from the implant/injection site boundary upon release from injectable, phase inverting poly(lactic acid-co-glycolic acid) (PLGA) implants. Fluorescein-loaded PLGA solutions were injected into poly(acrylamide) phantoms, and the constructs were treated daily for 14 days with ultrasound at 2.2 W/cm2 for 10 minutes. The 2D distribution of fluorescein within the phantoms was quantified using fluorescence imaging. Implants receiving ultrasound irradiation showed a 1.7-5.6 fold increase (p < 0.05) in fluorescence intensity and penetration distance, with the maximum increase observed 5 days post-implantation. However, this evidence was not seen when the same experiment was also carried out in phosphate buffer saline (pH 7.4). Results suggest an active role of ultrasound in local molecular transport in the phantom. An increase of fluorescein release and penetration depth in phantoms can be accomplished through brief application of ultrasound. This simple technique offers an opportunity to eventually enhance the therapeutic efficacy and broaden the application of local drug delivery systems.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.