The aim of this study is to detect preeclampsia-related cardiac dysfunction within 24-48 hours of delivery in newborns born from preeclamptic mothers. Forty newborns from mildly preeclamptic mothers formed the study group and the control group was formed by 40 healthy newborns. Cardiac function for the groups were evaluated using conventional echocardiography and myocardial performance index (MPI) within the first 24-48 hours of their lifetime and the results of both groups were compared. A significant difference between the groups was observed especially in the PW Doppler MPI measurements (the left ventricle MPI 0.37 ± 0.09 and 0.26 ± 0.11, p < .001; the right ventricle MPI 0.29 ± 0.08 and 0.26 ± 0.07, p < .035) for the control group and the study group. Elongation in the left and right ventricle MPI was detected to be more significant in terms of comparing systolic and diastolic functions to determine preeclampsia-related cardiac injury in newborns from preeclamptic mothers within the first 24-48 hours of their lifetime. Impact statement Today, the methods which may detect cardiac injury earlier than conventional echocardiographic methods are used for evaluating cardiac functions. Among them, myocardial performance index (MPI) measurement with PW Doppler is the most common ones. While studies are available in the literature evaluating foetal cardiac functions with MPI in foetuses of preeclamptic women, studies evaluating cardiac functions with MPI index within the first 24-48 hours in postnatal period are not available. This is the first study to detect cardiac injury by measuring cardiac functions of the newborns of preeclamptic babies using conventional echocardiography (EF, SF, mitral and tricuspid E/A) and myocardial performance index within the first 24-48 hours of life and compare these values with those of a control group composed of healthy newborns with similar demographic characteristics. According to the results of the study, elongation in right and left ventricle MPI was detected to be more significant compared to systolic and diastolic functions for determining preeclampsia-related cardiac injury in newborns of preeclamptic mothers within 24-48 hours of delivery. Ventricle functions of the newborns of preeclamptic mothers should also be evaluated with MPI measurement besides conventional echocardiographic measurements.
Introduction: The coronary arteries, which have to originate from the aorta, may sometimes rise from the pulmonary artery. This study evaluated clinical and diagnostic findings, treatment methods, and follow up of cases with anomalous coronary arteries arising from the pulmonary artery. Patients and methods: Eight patients with the diagnosis of anomalous left coronary artery from the pulmonary artery (ALCAPA) (N = 6) and anomalous right coronary artery from the pulmonary artery (ARCAPA) (N = 2), between January 2014 and January 2020 from a single center university hospital, were included in the study. Data from patients’ demographic characteristics, electrocardiography, echocardiography, angiographic findings, operation, hospitalization, and follow up were evaluated. Results: The study included eight patients (six females and two males) – six patients with ALCAPA and two with ARCAPA. The ages of the patients ranged between 3-135 (average: 53.25) months. The median body weight was calculated as 17.4 kg. Severe mitral valve insufficiency was detected in two patients and two other patients had a moderate degree of mitral insufficiency on echocardiography. Ejection fractions ranged between 16-74%. One patient had perimembranous malalignment large ventricular septal defect with pulmonary stenosis. Operative techniques were Takeuchi procedure (three patients), direct implantation (four patients), and left internal thoracic artery to left main coronary artery bypass (one patient). Mechanical cardiac support was not required in the postoperative period. Mortality did not occur. Mitral insufficiency and ejection fractions improved following correction of the coronary anatomy. Conclusion: It is important to diagnose the ALCAPA or ARCAPA, where the coronary artery originates from the pulmonary artery. Patients should be treated before congestive heart failure and fatal complications occur. Surgical correction should be planned regardless of symptom status, even though some of patients reach adulthood with an increased number of collaterals.
Background Transcatheter closure of perimembraneous ventricular septal defect still poses a challenge due to the adjacent structures of the tricuspid and aortic valves and the risk of atrioventricular block. We report our experience at 2 centers using the KONAR-MF (multifunctional occluder) ventricular septal defect device, which gained its CE mark in May 2018. Methods A retrospective study was carried out on all patients who underwent transcatheter ventricular septal defect closure with the KONAR-MF (multifunctional occluder) ventricular septal defect device at 2 centers. Results A total of 47 patients were identified. The median age and weight of the patients were 25.8 months and 11 kg. The ventricular septal defects that were closed in 5 cases were post-operative hemodynamically significant residual ventricular septal defects. Forty-eight devices were used in the 47 cases. As for the location of the ventricular septal defect, 40/48 (83.33%) ventricular septal defects were perimembranous and 8/48 (16.66%) were muscular. The percutaneous device closure was successful in 46 procedures (95.8%). Device embolization was observed in 2 patients, and a significant residual shunt was observed in 2 cases. In the follow-up, there was no enhancement in the residual shunt in the remaining cases. Temporary atrioventricular block occurred in 2 cases during the procedure and improved after long sheath withdrawal. Conclusion Soft, flexible, and low-profile KONAR-MF (multifunctional occluder) occluders ensure easy and safe implantation, and small sheath sizes allow for their use in small infants. Although near and mid-term follow-ups did not indicate any permanent atrioventricular block, a larger sample of patients and a longer follow-up period is necessary to understand long-term outcomes.
Although it is considered to be a benign condition, previous studies have shown that a subset of patients with mitral valve prolapse (MVP) may be at risk of ventricular arrhythmia and sudden cardiac death (SCD). Previous studies have suggested that the interval between the peak and the end of the T wave (Tp-e) can be used as a marker for the transmural dispersion of repolarization. Increased Tp-e interval and Tp-e/QT ratio are associated with ventricular arrhythmias and SCD. The aim of this study was to assess alterations in ventricular repolarization by using the Tp-e interval and Tp-e/QT ratio in children with MVP and to investigate their relationships with the degree of valvular regurgitation. This study prospectively investigated 110 children with MVP and 107 age- and sex-matched healthy control subjects. Tp-e interval, Tp-e/QT ratio, and QT and QTc dispersions were measured from a 12-lead electrocardiogram and compared between groups. QT and QTc dispersions, Tp-e interval, and Tp-e/QTc ratio were found to be significantly higher in patients with MVP. A positive correlation was found between Tp-e/QTc ratio and increase in the degree of mitral regurgitation (MR) (p < 0.05; r = 0.2). However, the degree of MR was not associated with QT, QTc, or Tp-e intervals; QT, QTc, or Tp-e dispersions; or Tp-e/QT ratio (all p values >0.05). Individuals with MVP may be more prone to ventricular arrhythmias due to prolonged QTd, QTcd, and Tp-e interval and increased Tp-e/QT and Tp-e/QTc ratios. Therefore, due to their longer life expectancy, children with MVP should be followed up on regarding life-threatening arrhythmias.
Treatment of the aneurysms comprising the aortic arch is challenging. Surgical reconstruction usually requires aortic cross-clamping, cardiac arrest, and even deep hypothermia for a bloodless field. In this report, we present our surgical technique providing normothermic ascending aorta, aortic arch, and proximal descending aorta replacement with selective cannulation and perfusion of the whole body.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.