The radio-frequency-induced plasma polymerization of allylamine has been investigated in the plasma-gas phase by mass spectrometry and at the plasma−solid interface by means of an ion flux probe and a quartz mass balance. The surface chemistry of the deposits has been determined by X-ray photoelectron spectroscopy. The objective of this study was to unravel the mechanism(s) by which allylamine plasma polymers form. The results are compared with those obtained in an earlier investigation of the plasma polymerization of acrylic acid. In the plasma-gas phase, evidence is provided for reactions between cations and intact neutral monomers (allylamine). These oligomerization reactions were found to be relatively power-insensitive compared with those seen in plasmas of acrylic acid, as was the gas-phase concentration of the intact neutral monomer. At the polymer surface, ion fluxes were found to increase with plasma input power (P) from 6.6 × 1016 ions m-2 s-1 at 1 W to 1.4 × 1018 ions m-2 s-1 at 14 W. The ionic mass transport to the polymer surface (ion mass flux) was calculated by multiplying the measured ion flux by the average ion mass (determined by mass spectrometry). At P = 1 W, the ion mass flux was 11.7 μm m-2 s-1, and at 14 W, the ion mass flux was 226.6 μm m-2 s-1. These values differed from the total mass deposition rates measured by the quartz mass balance, which were 18.7 and 127.1 μm m-2 s-1, respectively. However, the relationship found between the ion mass flux, the mass deposition rate, and P was complex, and it is shown that, at very low P (<1 W), the ion mass flux is sufficient to account for all of the deposit.
Ion Ñux, mass spectral and mass deposition rate measurements have been made in radiofrequency-induced continuous-wave plasmas of acrylic acid. At 1 W input power, an ion Ñux of 0.05 ^0.1 ] 1018 ions m~2 s~1 was measured for acrylic acid. At this power, ions corresponding to (2M ] H)`and (3M ] H)`were prominent in the positive-ion mass spectrum. When this spectrum was corrected for the transmission function of the quadrupole mass spectrometer (conservatively taken as intensity P m~1), it was evident that the cationic portion of plasma contained many ions of high m/z, as opposed to small fragments of acrylic acid. The m/z of the " average Ï ion was calculated as 115. The mass of ions arriving at a solid surface in the centre of the plasma was then calculated by multiplying the Ñux by the average mass to give 9.6 lg m~2 s~1. This value represents a signiÐcant fraction of the total mass deposited, determined by means of a quartz crystal mass balance (45.5 lg m~2 s~1). Repeating the calculation for a 5 W plasma yields an ion mass Ñux of 39.6 lg m~2 s~1 (measured mass deposition of 57.3 lg m~2 s~1). At 15 W, the calculated mass deposited (based on ion Ñux) exceeds that measured by the quartz mass balance. The " average Ï ion mass decreased as plasma input power increased.Based on these data, and XPS measurements of the solid-phase deposit we make a Ðrst attempt at describing semi-quantitatively the possible role of ions in deposit formation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.