A 10-month pilot study compared the performance of conventional granular media filtration (CGMF) with granular media filtration with preozonation (OGMF) to determine the effects of preozonation on filter performance. Filtration recoveries were lower for OGMF compared to CMGF when operated at a loading rate of 18.3 m/h. Operation at 18.3 m/h met turbidity requirements for California Department of Public Health Title 22 unrestricted reclaimed water requirements for both OGMF and CGMF. Preozonated secondary effluent at a transferred dose of 3 mg/L resulted in an increase in ultraviolet transmissivity (UVT) of approximately 6% and greater than 5-log inactivation of male-specific bacteriophage MS2. Wet weather flow events resulted in UVT decrease and a decline in MS2 inactivation to less than 3 log attributed to higher ozone demand in the secondary effluent. Preozonation increased N-nitrosodimethlyamine (NDMA) concentration approximately 10 times, but subsequent filtration reduced levels to secondary effluent values. A net increase in NDMA was observed at times.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.