The inflammatory response is modulated through interactions among the nervous, endocrine, and immune systems. Intercommunication between immune cells and the autonomic nervous system is a growing area of interest. Spatial and temporal information about inflammatory processes is relayed to the central nervous system (CNS) where neuroimmune modulation serves to control the extent and intensity of the inflammation. Over the past few decades, research has revealed various routes by which the nervous system and the immune system communicate. The CNS regulates the immune system via hormonal and neuronal pathways, including the sympathetic and parasympathetic nerves. The immune system signals the CNS through cytokines that act both centrally and peripherally. This review aims to introduce the concept of neuroimmune interaction and discuss its potential clinical application, in an attempt to broaden the awareness of this rapidly evolving area and open up new avenues that may aid in the treatment of inflammatory diseases.
Bone cement implantation syndrome (BCIS) is a rare but potentially fatal intraoperative complication that occurs in patients undergoing cemented orthopedic surgeries. Lack of a robust definition of the syndrome due to rarity of the condition has probably contributed to under reporting of cases. We report a case of a 72-year-old woman hospitalized for an elective orthopedic procedure with a postoperative course complicated by BCIS requiring supportive care in the intensive care unit setting.
Background: Point-of-care (POC) glucometers are commonly used in intensive care units (ICUs). The Centers for Medicare & Medicaid Services have called into question the accuracy of POC glucometers in critically ill patients. This study sought to identify specific characteristics within our facility’s ICU patients that were associated with inaccuracies in POC glucose measurements. Methods: We conducted a prospective cohort study that compared POC capillary blood glucose samples with venous samples collected in our ICU. All nonpregnant patients >18 years old admitted to the ICU with orders for daily laboratory testing that included blood glucose were eligible for inclusion. Results: A total of 46 patients were enrolled and 85 samples were collected. The mean difference between venous and POC samples was 5.23 mg/dL (95% CI, 3.16-7.3 mg/dL). Measurement inaccuracies would have altered treatment in 7/85 instances (8.2%). The only clinically significant inaccuracy found was the omission of 2 units of insulin in 1 hyperglycemic patient. Measurement inconsistencies generally underestimated low blood glucose values (2/2 instances) and overestimated high blood glucose values (4/5 instances). Conclusions: In our study, the mean difference between venous and POC glucose samples was small. Similarly, measurement inaccuracies that would have altered treatment were rare and only one instance was deemed clinically significant. We conclude that POC capillary glucose testing within our cohort and in similar critically ill patients is likely safe and effective.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.