High atomic number and density of dental implants leads to major problems at providing an accurate dose distribution in radiotherapy and contouring tumors and organs caused by the artifact in head and neck tumors. The limits and deficiencies of the algorithms using in the treatment planning systems can lead to large errors in dose calculation, and this may adversely affect the patient's treatment. In the present study, four commercial dental implants were used: pure titanium, titanium alloy (Ti‐6Al‐4V), amalgam, and crown. The effects of dental implants on dose distribution are determined with two methods: pencil beam convolution (PBC) algorithm and Monte Carlo code for 6 MV photon beam. The central axis depth doses were calculated on the phantom for a source–skin distance (SSD) of 100 cm and a 10×10 cm2 field using both of algorithms. The results of Monte Carlo method and Eclipse TPS were compared to each other and to those previously reported. In the present study, dose increases in tissue at a distance of 2 mm in front of the dental implants were seen due to the backscatter of electrons for dental implants at 6 MV using the Monte Carlo method. The Eclipse treatment planning system (TPS) couldn't precisely account for the backscatter radiation caused by the dental prostheses. TPS underestimated the back scatter dose and overestimated the dose after the dental implants. The large errors found for TPS in this study are due to the limits and deficiencies of the algorithms. The accuracy of the PBC algorithm of Eclipse TPS was evaluated in comparison to Monte Carlo calculations in consideration of the recommendations of the American Association of Physicists in Medicine Radiation Therapy Committee Task Group 65. From the comparisons of the TPS and Monte Carlo calculations, it is verified that the Monte Carlo simulation is a good approach to derive the dose distribution in heterogeneous media.PACS numbers: 87.55.K‐
Background/aim: To investigate the effect of positron emission tomography-computed tomography (PET/CT)-based contouring on dosimetric parameters in rectal cancer patients undergoing preoperative intensity-modulated radiation therapy (IMRT).
Materials and methods:Preoperative radiation therapy plans with conformal radiotherapy (CRT) or IMRT were created and examined according to the CT-and PET/CT-based contouring of 20 rectal cancer patients, retrospectively.
Results:The target volumes delineated with PET/CT were significantly larger than the volumes created by CT (P = 0.043). Dose delivered to 98% of the planning target volume was high in IMRT planning contouring with CT and PET/CT compared with CRT planning, but the difference was not statistically significant (P = 0.056). Percent volumes receiving 105% of dose and 110% of dose were low in IMRT planning when compared with CRT (P < 0.0001 and P = 0.044, respectively). The volumes receiving 45 Gy for the small intestine, femur heads, and bladder and the maximum dose received by the bladder were significantly lower in IMRT.
Conclusion:We showed that the target volumes created with PET/CT are significantly larger than the target volumes created with CT and that IMRT provides lower radiation exposure to the tumor-free tissues compared to the CRT planning. The dosimetric results primarily favor IMRT planning in rectal cancer patients and consequently present the significant alteration in target volumes.
Purpose: To investigate high conformality on target coverage and the ability on creating strict lung dose limitation of intensitymodulated radiation therapy in malignant pleural mesothelioma. Patients and Methods: Twenty-four radiation therapy plannings were evaluated and compared with dosimetric outcomes of conformal radiation therapy and intensity-modulated radiation therapy. Hemithoracal radiation therapy was performed on 12 patients with a fraction of 1.8 Gy to a total dose of 50.4 Gy. All organs at risk were contoured. Radiotherapy plannings were differed according to the technique; conformal radiation therapy was planned with conventionally combined photon-electron fields, and intensity-modulated radiation therapy was planned with 7 to 9 radiation beam angles optimized in inverse planning. Strict dose-volume constraints were applied. Results: Intensity-modulated radiation therapy was statistically superior in target coverage and dose homogeneity (intensity-modulated radiation therapyplanning target volume 95 mean 100%; 3-dimensional conformal radiation therapy-planning target volume 95 mean 71.29%, P ¼ .0001; intensity-modulated radiation therapy-planning target volume 105 mean 11.14%; 3-dimensional conformal radiation therapy-planning target volume 105 mean 35.69%, P ¼ .001). The dosimetric results of the remaining lung was below the limitations on intensity-modulated radiation therapy planning data (intensity-modulated radiation therapy-lung mean dose mean 7.5 [range: 5.6%-8.5%]; intensity-modulated radiation therapy-lung V5 mean 55.55% [range: 47%-59.9%]; intensity-modulated radiation therapy-lung V20 mean 4.5% [range: 0.5%-9.5%]; intensity-modulated radiation therapy-lung V13 mean 13.43% [range: 4.2%-22.9%]). Conclusion: With a complex and large target volume of malignant pleural mesothelioma, intensitymodulated radiation therapy has the ability to deliver efficient tumoricidal radiation dose within the safe dose limits of the remaining lung tissue.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.