Introduction
In complex and deformed knees, soft tissue release (STR) is required to obtain symmetry in the femorotibial gap. The objective of this study was to attempt to predict the need for soft tissue release using surgical navigation in total knee replacement (TKR).
Methods
Prospective and non-randomized study. One hundred thirty knees. At the start of navigation, an attempt was made to correct the femorotibial mechanical axis by applying force to the medial or lateral side of the knee (varus-valgus stress angle test). A gap balanced technique with computer-assisted surgery (CAS) was performed in all cases. The ligaments were tensioned, and using CAS visualization and control, progressive STR was performed in the medial or lateral side until a symmetry of the femorotibial gap was achieved.
Results
Eighty-two patients had a varus axis ≥ 3° and 38 had a valgus axis (P < 0.001). STR was performed under navigation control in 38.5% of cases, lateral release (LR) in 12 cases, and medial release (MR) in 38 cases. After performing the varus-valgus stress angle test (VVSAT), the axis of 0° could be restored at some point during the manoeuvre in 28 cases. STR was required in 44.6% of varus cases and 27% of valgus cases (P = 0.05). A significant relationship was found between the previous deformity and the need for MR (P < 0.001) or LR (P = 0.001). STR was more common in male patients (P = 0.002) and as obesity increased.
Conclusion
This study shows that pre-operative factors favouring the need to perform STR in a TKR implant can be defined.
Summary
Background
One of the possible causes of dissatisfaction reported by many patients after total knee replacement (TKR) is the lack of agreement between component size and bone structure. To avoid this complication and facilitate the procedure, preoperative planning with digitized templates is recommended. Surgical navigation indicates the best position and the most adequate size of arthroplasty and may therefore replace preoperative radiographic measurement. The objective of the study was to check agreement between the sizes of TKR components measured before surgery with digitized templates, the size recommended by the navigation and sizes actually implanted.
Methods
In 103 patients scheduled for TKR, preoperative full-limb radiography was performed to measure the mechanical and anatomical axes of the limb, femur and tibia. The most adequate size of the femoral and tibial components was planned by superimposing digitized templates. The size recommended in navigation and the size of the finally implanted components were also recorded.
Results
A high level of agreement was found between the sizes of femoral and tibial components measured by X-rays and in navigation (0.750 and 0.772, respectively) (intraclass correlation and Cronbach's alpha). Agreement between the sizes recommended by X-rays and navigation and those finally implanted was 0.886 for the femur and 0.891 for the tibia. Agreement levels were not different in cases with prior deformities of limb axis.
Conclusions
The high level of agreement found in component sizes between radiographic measurement with digitized templates and navigation suggests that preoperative X-ray measurement is not needed when navigation is used for placement of implants during TKR.
The translational potential of this article
Computer-assisted surgery may avoid preoperative measurement with templates in TKR.
ObjectiveTo demonstrate that postoperative computed tomography (CT) is not needed if navigation is used to determine the rotational position of the femoral component during total knee replacement (TKR).MethodsPreoperative CT, navigational, and postoperative CT data of 70 TKR procedures were analysed. The correlation between the rotational angulation of the femur measured by CT and that measured by perioperative navigation was examined. The correlation between the femoral component rotation determined by navigation and that determined by CT was also assessed.ResultsThe mean femoral rotation determined by navigation was 2.64° ± 4.34°, while that shown by CT was 6.43° ± 1.65°. Postoperative rotation of the femoral component shown by CT was 3.09° ± 2.71°, which was closely correlated with the angle obtained through the intraoperative transepicondylar axis by navigation (Pearson’s R = 0.930).ConclusionsNavigation can be used to collect the preoperative, intraoperative, and postoperative data and final position of the TKR. The rotation of the femoral component can be determined using navigation without the need for CT.
TKR surgery modifies preoperative tibial torsion. Neither mechanical instrumentation nor navigation surgery precisely reproduces the rotational axis of the leg.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.