A free-flooded ring (FFR) transducer can generate low-frequency sound in a small device and has a wide operating frequency bandwidth. Many studies have been performed that can predict the characteristics of an FFR transducer using analytical techniques and an equivalent circuit model (ECM), and methods to predict properties using numerical simulations have recently been developed. However, an ECM, a type of lumped parameter model (LPM), is still widely used to interpret the properties of such transducers in the design process. In this study, the authors investigated an ECM of an FFR transducer. The ECM consists of three parts: the piezoelectric ring, the cylindrical cavity, and the radiation load. Moreover, it can be included readily in a circuit to drive an FFR transducer. Additionally, an LPM was proposed, considering the mutual radiation loads, to improve the accuracy of the model. Each model was tested in comparisons with the finite element method; it was confirmed that an LPM could predict the properties of an FFR transducer with much better accuracy than an ECM. The LPM developed can save much time in designing FFR transducers.
The free-flooded ring (FFR) transducer is the well-known low-frequency sound sources in underwater because of its broad operating frequency bandwidth and relatively small size. Many previous studies have been performed that predict the characteristics of an FFR transducer using an equivalent circuit model (ECM), a type of lumped parameter model (LPM) because an ECM is widely used to understand the properties of such transducers in the design process. However, it is quite difficult to predict the characteristics of an FFR transducer because the acoustic field is generated from its top and bottom openings, connected by the inner fluid, as well as the cylindrical ring surface. In this study, the authors investigated an ECM of an FFR transducer. The ECM consists of three parts: the piezoelectric ring, the cylindrical cavity, and the radiation load. In addition, an LPM which can consider mutual radiation loads was proposed to improve the accuracy of the model. The proposed models were compared and verified using commercial finite element method (COMSOL Multiphysics). We confirmed that LPM can predict characteristics of FFR transducer more accurately than ECM. [This work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIP) (Grant No. 2016R1E1A2A02945515).]
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers