AIMTo reduce post treatments of kyphoplasty, as a common treatment for osteoporotic vertebrae.METHODSThis study suggests a new method for treating vertebrae by setting the hexagonal porous structure instead of the rigid bone cement mass in the kyphoplasty (KP). The KP procedure was performed on the fresh ovine vertebra of the level L1. Micro finite element modeling was performed based on micro computed tomography of ovine trabecular cube. The hexagonal porous structure was set on one cube instead of the bone cement mass. For the implant designing, two geometrical parameters were considered: Spacing diameter and thickness.RESULTSThe results of micro finite element analyses indicated the improvement in the mechanical behavior of the vertebra treated by the hexagonal porous structures, as compared to those treated by vertebroplasty (VP) and KP under static loading. The improvement in the mechanical behavior of the vertebra, was observed as 54% decrease in the amount of maximum Von Misses stress (improvement of stress distribution), in trabecular cube with embedded hexagonal structure, as compared to VP and KP. This is comparable to the results of the experimental study already performed; it was shown that the improvement of mechanical behavior of the vertebra was observed as: 83% increase in the range of displacements before getting to the ultimate strength (increasing the toughness) after setting hexagonal pearls inside vertebrae. Both the material and geometry of implant influenced the amount of Von Mises stress in the structure.CONCLUSIONThe new proposed method can be offered as a substitute for the KP. The implant geometry had a more obvious effect on the amount of Von Mises stress, as compared to the implant material.
The vertebroplasty (VP) and kyphoplasty (KP) are two minimally invasive surgeries using cement augmentation to treat the osteoporotic vertebrae in elderlies in order to relieve pain and prevent the continuation of microfractures. Biomechanists have always tried to assess the mechanical behavior of vertebrae after cement augmentation by using both the experimental and theoretical methods such as finite element modeling (FEM). In this study, 31 related articles using FEM in analyzing the VP and KP have been reviewed. This study included two main categories of spinal load distribution and tension in vertebrae after the VP and KP operations. This could be obtained by conducting FEM on the whole spine or other sectors of it such as intervertebral disc (IVD) or end plates (EPs). This study also referred to articles predicting the probability of adjacent fractures following VP and KP. The most common software employed in FEM was ABAQUS, applied for static and dynamic loads’ analyses. It was found that most of the reviewed articles adopted reverse engineering techniques by converting 2D computed tomography (CT) scan images into 3D reconstructed models. The material properties were generally taken from the literature. In more than 80% of studies, the model geometry was based on CT data of the spine. Almost 45% of the studies have attempted to compare the simulated vertebra after augmentation with experimental results taken from the literature (5% of the reviewed articles) or their own experimental tests (40% of the reviewed articles).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.