A large number of studies during the past two decades have demonstrated the efficacy and safety of sevoflurane across patient populations. Clinical researchers have also investigated the effects of sevoflurane, its hemodynamic characteristics, its potential protective effects on several organ systems, and the incidence of delirium and cognitive deficiency. This review examines the clinical profiles of sevoflurane and other anesthetic agents, and focuses upon emerging topics such as organ protection, postoperative cognitive deficiency and delirium, and novel ways to improve postanesthesia outcomes.
With an estimated worldwide volume of 266 million surgeries in 2015, the call for general inhalation anesthesia is considerable. However, widely used volatile anesthetics such as N 2 O and the highly fluorinated gases sevoflurane, desflurane, and isoflurane are greenhouse gases, ozone-depleting agents, or both. Because these agents undergo minimal metabolism in the body during clinical use and are primarily (≥95%) eliminated unchanged via exhalation, waste anesthetic gases (WAGs) in operating rooms and postanesthesia care units can pose a challenge for overall elimination and occupational exposure. The chemical properties and global warming impacts of these gases vary, with atmospheric lifetimes of 1−5 years for sevoflurane, 3−6 years for isoflurane, 9−21 years for desflurane, and 114 years for N 2 O. Additionally, the use of N 2 O as a carrier gas for the inhalation anesthetics and as a supplement to intravenous (IV) anesthetics further contributes to these impacts. At the same time, unscavenged WAGs can result in chronic occupational exposure of health care workers to potential associated adverse health effects. Few adverse effects associated with WAGs have been documented, however, when workplace exposure limits are implemented. Specific measures that can help reduce occupational exposure and the environmental impact of inhaled anesthetics include efficient ventilation and scavenging systems, regular monitoring of airborne concentrations of waste gases to remain below recommended limits, ensuring that anesthesia equipment is well maintained, avoiding desflurane and N 2 O if possible, and minimizing fresh gas flow rates (eg, use of low-flow anesthesia). One alternative to volatile anesthetics may be total intravenous anesthesia (TIVA). While TIVA is not associated with the risks of occupational exposure or atmospheric pollution that are inherent to volatile anesthetic gases, clinical considerations should be weighed in the choice of agent. Appropriate procedures for the disposal of IV anesthetics must be followed to minimize any potential for negative environmental effects. Overall, although their contributions are relatively low compared with those of other human-produced substances, inhaled anesthetics are intrinsically potent greenhouse gases and pose a risk to operating-room personnel if not properly managed and scavenged. Factors to reduce waste and minimize the future impact of these substances should be considered.
Introduction: It is desirable to minimise exposure of personnel to halogenated inhaled anaesthetics in the operating room to avoid deleterious short-term and long-term health effects. The objective of this study was to determine whether, while filling anaesthetic vaporizers with sevoflurane using AbbVie's closed vaporizer filling system (Quik-Fil TM), concentrations of sevoflurane in ambient air remained at or below recommended levels when measured at different operator heights. Methods: Nine filling runs were conducted, with measurement heights of 95, 130, 140, 150, 160, and 185 cm. Within each 15-min run, five vaporizers were sequentially filled from bottles of sevoflurane with the closed valving system. Ambient-air sevoflurane concentration in the breathing zone was continuously measured once per second by using a MIRAN SapphIRe 205BXL portable ambient air analyser. Results: The use of the closed filling system maintained a level of waste anaesthetic gas exposure that was well below (mean, 0.10 ppm; maximum, 0.16 ppm) the recommended shortterm value of 20 ppm average for 15 min provided by the Swedish Work Environment Authority and also fell below the US limit of a time-weighted average of 2 ppm provided by the National Institute for Occupational Safety and Health. Exposure to sevoflurane appeared to be independent of the height at which the measurement was made. Conclusions: The presence of sevoflurane in the work environment while using the closed filling system maintains a level of waste anaesthetic gas exposure well below the recommended levels at all tested operator heights.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.