Purpose To compare the efficacy and safety of intraocular lens (IOL) repositioning and IOL exchange for the treatment of patients with IOL dislocation. Methods We systematically searched for relevant publications in English or Chinese in MEDLINE, Embase, the Cochrane Central Register of Controlled Trials, WHO International Clinical Trial Registration Platform, Clinical Trial.gov, China Biology Medicine Database, China National Knowledge Infrastructure Database and grey literature sources. Study quality was assessed using the STROBE template for observational studies and the Cochrane template for randomized controlled trials (RCTs). Data were meta-analyzed using RevMan 5.3. Results The review included 14 English-language studies reporting 1 RCT and 13 retrospective case series involving 1,082 eyes. Average follow-up time was 13.7 months. Pooled analysis of 10 studies showed that the two procedures had a similarly effect on best corrected visual acuity (MD -0.00, 95%CI: -0.08 to 0.08, P = 0.99). Pooled analysis of nine studies showed no significant difference in incidence of IOL redislocation (RR 2.12, 95%CI 0.85 to 5.30, P = 0.11); pooled analysis of seven studies showed greater extent of incidence of cystoid macular edema in IOL exchange (RR 0.47, 95%CI 0.21 to 1.30, P = 0.06). Pooled analysis of three studies showed greater extent of incidence of anterior vitrectomy in IOL exchange (RR 0.11, 95%CI 0.04 to 0.33, P<0.0001). Pooled analysis of two studies showed greater postoperative spherical equivalents in IOL repositioning (MD 1.02, 95%CI 0.51 to 1.52, P<0.0001). pooled analysis suggested no significant differences between the two procedures in terms of intraocular pressure, endothelial cell density, surgically induced astigmatism, or incidence of retinal detachment, intraocular hemorrhage or pupillary block. Conclusion IOL repositioning and exchange are safe and effective procedures for treating IOL dislocation. Neither procedure significantly affects best corrected visual acuity and IOL redislocation. IOL exchange was superior to repositioning in terms of postoperative SE, but IOL repositioning was associated with lower incidence of anterior vitrectomy, potentially lower incidence of cystoid macular edema.
Background The use of capsular tension ring (CTR) implantation to treat cataract patients with weak zonules is still controversial. The aim of this study was to examine the effects of CTR implantation on capsular stability after phacoemulsification in patients with weak zonules, especially patients who have undergone pars plana vitrectomy (PPV) or those who suffer from severe myopia. Methods A total of 42 patients who underwent phacoemulsification and received an intraocular lens (IOL) were randomized to undergo CTR implantation or not. The control and CTR groups were compared in terms of uncorrected distant visual acuity (UDVA), best corrected distant visual acuity (BCDVA), refractive prediction error, the area of anterior capsulorhexis, and IOL inclination angle. Follow-up visits were conducted postoperatively at 1 day, 1 week, 1 month and 3 months. Subgroup analyses were performed based on PPV and severe myopia. Results Surgery significantly improved UDVA and BCDVA to similar extents in CTR and control patients, and refraction prediction error was similar between the two groups at all follow-up times. At 3 months after surgery, the area of anterior capsulorhexis was significantly larger in CTR patients than in controls (p = 0.0199). These differences were also significant between the subgroups of patients with severe myopia. Vertical IOL inclination was less within CTR groups at 3 months after surgery, especially in patients with severe myopia (p = 0.0286). At 1 week postoperatively, the proportion of individuals whose posterior lens capsule that had completely adhered to the posterior IOL surface was significantly higher among CTR patients (p = 0.023). No serious surgical complications were observed. Conclusion CTR implantation can benefit cataract patients with weak zonules by maintaining the shape of the capsular bag, reducing capsule shrinkage and stabilizing IOL inclination. Trial registration Chinese Clinical Trial Registry ChiCTR-INR-17011217, date of registration April 22, 2017, prospectively registered.
Background: The use of capsular tension ring (CTR) implantation to treat cataract patients with weak zonules is still controversial. The aim of this study was to examine the effects of CTR implantation on capsular stability after phacoemulsification in patients with weak zonules, especially patients who have undergone pars plana vitrectomy (PPV) or those who suffer from severe myopia.Methods: A total of 42 patients who underwent phacoemulsification and received an intraocular lens (IOL) were randomized to undergo CTR implantation or not. The control and CTR groups were compared in terms of uncorrected distant visual acuity (UDVA), best corrected distant visual acuity (BCDVA), refractive prediction error, the area of anterior capsulorhexis, and IOL inclination angle. Follow-up visits were conducted postoperatively at 1 day, 1 week, 1 month and 3 months. subgroup analyses were performed based on PPV and severe myopia. Results: Surgery significantly improved UDVA and BCDVA to similar extents in CTR and control patients, and refraction prediction error was similar between the two groups at all follow-up times. At 3 months after surgery, the area of anterior capsulorhexis was significantly larger in CTR patients than in controls (p = 0.0199). These differences were also significant between the subgroups of patients with severe myopia. Vertical IOL inclination was less within CTR groups at 3 months after surgery, especially in patients with severe myopia (p = 0.0286). At 1 week postoperatively, the proportion of individuals whose posterior lens capsule that had completely adhered to the posterior IOL surface was significantly higher among CTR patients (p = 0.023). No serious surgical complications were observed.Conclusion: CTR implantation can benefit cataract patients with weak zonules by maintaining the shape of the capsular bag, reducing capsule shrinkage and stabilizing IOL inclination.Trial registration: Chinese Clinical Trial Registry ChiCTR-INR-17011217, date of registration April 22, 2017, prospectively registered.
Background: Patients who had previously undergone pars plana vitrectomy (PPV) or who had severe myopia may have weaker zonules, for which a capsular tension ring (CTR) implantation is still controversial. This study is to test the effect of CTR implantation on capsular stability after phacoemulsification in those patients. Methods: A total of 42 patients who underwent phacoemulsification and received an intraocular lens (IOL) were randomized to undergo CTR implantation or not. The primary outcomes were uncorrected distant visual acuity (UDVA), best corrected distant visual acuity (BCDVA), refractive prediction error, the area of anterior capsulorhexis, and IOL inclination angle. Follow-up visits were conducted postoperatively at 1 day, 1 week, 1 month and 3 months. Outcomes were compared between all CTR and control patients, as well as between subgroups who had previously undergone PPV or who had severe myopia. Results: Surgery significantly improved UDVA and BCDVA to similar extents in CTR and control patients, and refraction prediction error was similar between the two groups at all follow-up times. At 3 months after surgery, the area of anterior capsulorhexis was significantly larger in CTR patients than in controls (p = 0.0199). These differences were also significant between the subgroups of patients with strong myopia. Vertical IOL inclination was less within CTR groups at 3 months after surgery, especially in patients with severe myopia(p=0.0286). At 1 week postoperatively, the proportion of individuals whose posterior lens capsule that had completely adhered to the posterior IOL surface was significantly higher among CTR patients (p = 0.023). No serious surgical complications were observed. Conclusion: CTR implantation can benefit cataract patients with weak zonules by maintaining the shape of the capsular bag, reducing capsule shrinkage and stabilizing IOL inclination.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.