Preventive health check in patients with diabetes 1133© 1996-2020 6.2. Debate on the use of CUSIP for CVD risk assessment 6.3. Measurement of Carotid Ultrasound Image-based phenotypes 6.4. Validation of Automated Full-length Measurement 7. Integrated Screening Tools for CVD risk assessment 8. Discussion 8.1. A special note on clinical trials and case reports in preventive screening 8.2. Morphology-based risk assessment methods 8.3. Financial burden of diabetes mellitus in India 8.4. Manifestations 9. Conclusion 10. Disclosures 11. References
Background: Atherosclerotic cardiovascular disease (CVD) is severe and early-stage detection is crucial. Elevated arterial stiffness observed in childhood atherosclerosis is associated with CVD. Stiffness is an efficient marker of CVD in hypertensives.Assessment of stiffness includes waveform analysis and image-based techniques. Researchers observed several challenges: realtime application, accuracy, operator variability, image quality, scanning procedure, instrument variability and deficiency of standardized procedure in the assessment. Methods: We searched PubMed, Embase and Cochrane online library from inception up to July 2020. Multiple articles on stiffness, pulse wave velocity, assessment and deep learning (DL)-based methods were analysed. Above all, a DL-based technique for assessment of stiffness from cine-loop is proposed. The method includes region of interest (ROI) localisation in multiple frames, segmentation of lumen and parameter estimation. Results: Compared to conventional methods DL provide improved result in lumen diameter and intima-media thickness (IMT) measurements. Using convolutional neural network (CNN), IMT error was 0.08 mm. Further, error using extreme learning machine-autoencoder was 5.79±34.42 \mum. Furthermore, Jaccard index and Dice similarity in fully convolution neural network (FCN) manifested 0.94 and 0.97 for lumen segmentation respectively. Conclusion: This paper focuses on the association of stiffness and atherosclerosis leading to CVD. Success of image-based stiffness estimation depends on the visibility and orientation of arteries, operator experience, intensity variation, shadowing, artefacts, and noise. Traditional methods include transformations to compensate for these challenges. The success of DL-based techniques in segmentation and localisation inspired application in stiffness measurement. DL is used to estimate stiffness from cine-loop.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.