Nature consists of numerous solutions to overcome challenges in designing artificial systems. Various actuation mechanisms have been implemented in microrobots to mimic the motion of microorganisms. Such bio-inspired designs have contributed immensely to microscale developments. Among the actuation mechanisms, magnetic actuation is widely used in bio-inspired microrobotic systems and related propulsion mechanisms used by microrobots to navigate inside a magnetic field and are presented in this review. In addition, the considered robots are in microscale, and they can swim inside a fluidic environment with a low Reynolds number. In relation to microrobotics, mimicry of bacteria flagella, sperm flagella, cilia, and fish are significant. Due to the fact that these biological matters consist of different propulsion mechanisms, the effect of various parameters was investigated in the last decade and the review presents a summary that enhances understanding of the working principle of propulsion mechanisms. In addition, the effect of different parameters on the various speeds of the existing microrobots was analyzed to identify their trends. So, the swimming speeds of the microrobots show an upward trend with increasing body length, frequency, magnetic flux density, and helix angle. Microfabrication techniques play a significant role in the microscale because the device designs are highly dependent on the availability of the techniques. The presented microrobots were manufactured by 3D/4D photolithography and rapid prototyping techniques. Proper materials enable effective fabrication of microrobots using the mentioned techniques. Therefore, magnetically active material types, matrix materials, biocompatible and biodegradable materials are presented in this study. Utilizing biocompatible and biodegradable materials avoids adverse effects to the organs that could occur otherwise. In addition, magnetic field generation is significant for the propulsion of such microrobots. We conclude the review with an overview of the biomimicry of microrobots and magnetically actuated robot propulsion.
Multiple robots are used in robotic applications to achieve tasks that are impossible to perform as individual robotic modules. At the microscale/nanoscale, controlling multiple robots is difficult due to the limitations of fabrication technologies and the availability of on-board controllers. This highlights the requirement of different approaches compared to macro systems for a group of microrobotic systems. Current microrobotic systems have the capability to form different configurations, either as a collectively actuated swarm or a selectively actuated group of agents. Magnetic, acoustic, electric, optical, and hybrid methods are reviewed under collective formation methods, and surface anchoring, heterogeneous design, and non-uniform control input are significant in the selective formation of microrobotic systems. In addition, actuation principles play an important role in designing microrobotic systems with multiple microrobots, and the various control systems are also reviewed because they affect the development of such systems at the microscale. Reconfigurability, self-adaptable motion, and enhanced imaging due to the aggregation of modules have shown potential applications specifically in the biomedical sector. This review presents the current state of shape formation using microrobots with regard to forming techniques, actuation principles, and control systems. Finally, the future developments of these systems are presented.
This article presents the design of a magnetic microactuator comprising soft magnetic material blocks and flexible beams. The modular layout of the proposed microactuator promotes scalability towards different microrobotic applications using low magnetic fields. The presented microactuator consists of three soft magnetic material (Ni-Fe 4750) blocks connected together via two Polydimethylsiloxane (PDMS) semi-circular beams. A detailed design approach is highlighted giving considerations toward compactness, range of motion and force characteristics of the actuator. The actuator displacement and force characteristics are approximately linear in the magnetic field strength range of 80-160 kA/m. It can achieve maximum displacements of 111.6 µm (at 160 kA/m) during extension and 10.7 µm (at 80 kA/m) during contraction under no-load condition. The maximum force output of the microactuator, computed through a contact simulation, was 404.3 nN at a magnetic field strength of 160 kA/m. The microactuator achieved stroke angles up to 18.4 in a study where the microactuator was integrated with a swimming microrobot executing rowing motion using an artificial appendage, providing insight into the capabilities of actuating untethered microrobots.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.