The equivalent single-degree-of-freedom (SDOF) load transformation factor expressions of the simply supported, fixed end and simply-fixed one-way members subjected to air blast loading are derived by finite series-expansion method or finite point-fitting method. Moreover, figures are used to show the relative relationship between the load transformation factors KL and the ratio of stand-off distance to structural span (γ). The typical calculation conditions show that the load transformation factors are sensitive to the piecewise function of peak overpressure when γ is less than 0.5. The load transformation factor will be a smooth curve for peak overpressure adopting a single smooth continuous function. For the blast-resistant structural design, if the error of 3% in the elastic stage and 5% in the plastic stage can be allowed, γ = 1.0 is the demarcation point between near field blast and far field blast. In addition, if the error of 0.5% can be allowed, γ ≥ 2.0 can be treated as the far field blast. The calculation results of far field blast show that the values of KL of simply supported, simply-fixed, and fixed-end members are 0.64, 0.58, and 0.54, respectively, which means that the load transformation factor is insensitive to the selection of shape function in vibration mode function or static deflection curve function. The calculation accuracy of KL expression for simply supported beam structure in this paper has been verified through near field blast experiments. This paper provides a clear numerical definition for the distinction between near field and far field explosions. It provides qualification criteria for analyzing explosion categories in blast-resistant structural design and a reference for the selection of theoretical calculation formulas.
In this article, a new type of reticulated joint, named the steel–concrete composite reticulated shell joint, is proposed. The proposed reticulated shell joint consists of an inner circular steel pipe, an outer circular steel pipe, a steel cover plate, and internal concrete. Five test specimens were tested under axial compression. The variable study included the wall thickness of the inner and outer circular steel pipes and the radius of the inner circular steel pipe. The test specimens exhibited a high bearing capacity and good plastic deformation ability under axial compression. The test results show that the wall thickness of the outer circular steel pipe and the radius of the inner circular steel pipe have a great influence on the bearing capacity of the steel–concrete composite reticulated shell joint, while the wall thickness of the inner circular steel pipe has little influence on the bearing capacity of the steel–concrete composite reticulated shell joint. Based on the test of the steel–concrete composite reticulated shell joints under axial load, the three-dimensional nonlinear finite element model was used to analyze the mechanical properties of the steel–concrete composite reticulated shell joints under axial compression. The results of the finite element analysis showed good agreement with the experimental results. The formula for calculating the bearing capacity of the joint is derived. By comparing with the experimental results, the calculated results are basically consistent with the experimental results.
Glass-fiber reinforced polymer (GFRP) bars are increasingly widely used in slope support instead of steel bars or steel pipes. GFRP Bars are generally connected with the slope by combining conical nut and tray, but the tray stress still lacks corresponding theoretical calculation and strength verification methods. Therefore, assuming that the tray is an equal thickness thin plate, the internal force distribution of the tray is calculated using the thin plate bending and cavity expansion theory, and compared with the finite element numerical analysis results of the tray. The calculation and analysis show that the elastic theoretical solution of internal force distribution of equal thickness tray is basically the same as the numerical simulation solution of variable thickness tray. The tray loading and free surface are controlled by hoop tensile and radial compressive stress, respectively. The inner wall of the free surface of the tray is the weakest part of the tray, and the ultimate strength of a GFRP tray is 35.81–53.00% of the standard tensile strength of Φ20 GFRP bars by distortion energy density. This theoretical method can be used for stress analysis of variable thickness trays and has played technical support for promoting the application of GFRP bars in slope support.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.