Diagnostic abilities of ONH, RNFL, and GCC parameters of SDOCT to differentiate preperimetric glaucoma eyes from control eyes with large physiologic cupping were only moderate.
PurposeTo compare the abilities of peripapillary retinal nerve fiber layer (RNFL) parameters of spectral domain optical coherence tomograph (SDOCT) and scanning laser polarimeter (GDx enhanced corneal compensation; ECC) in detecting preperimetric glaucoma.MethodsIn a cross-sectional study, 35 preperimetric glaucoma eyes (32 subjects) and 94 control eyes (74 subjects) underwent digital optic disc photography and RNFL imaging with SDOCT and GDx ECC. Ability of RNFL parameters of SDOCT and GDx ECC to discriminate preperimetric glaucoma eyes from control eyes was compared using area under receiver operating characteristic curves (AUC), sensitivities at fixed specificities and likelihood ratios (LR).ResultsAUC of the global average RNFL thickness of SDOCT (0.786) was significantly greater (p<0.001) than that of GDx ECC (0.627). Sensitivities at 95% specificity of the corresponding parameters were 20% and 8.6% respectively. AUCs of the inferior, superior and temporal quadrant RNFL thickness parameters of SDOCT were also significantly (p<0.05) greater than the respective RNFL parameters of GDx ECC. LRs of outside normal limits category of SDOCT parameters ranged between 3.3 and 4.0 while the same of GDx ECC parameters ranged between 1.2 and 2.1. LRs of within normal limits category of SDOCT parameters ranged between 0.4 and 0.7 while the same of GDx ECC parameters ranged between 0.7 and 1.0.ConclusionsAbilities of the RNFL parameters of SDOCT and GDx ECC to diagnose preperimetric glaucoma were only moderate. Diagnostic abilities of the RNFL parameters of SDOCT were significantly better than that of GDx ECC in preperimetric glaucoma.
Purpose To compare the abilities of retinal nerve fiber layer (RNFL) parameters of spectral domain optical coherence tomograph (SDOCT) and scanning laser polarimeter (GDx enhanced corneal compensation; ECC) in detecting glaucoma. Methods In a cross-sectional study, 215 eyes of 165 subjects (106 eyes of 79 glaucoma patients and 109 eyes of 86 controls) referred by general ophthalmologists for glaucoma evaluation underwent RNFL imaging with SDOCT and GDx ECC. Ability of RNFL parameters of SDOCT to discriminate glaucoma eyes from control eyes was compared with that of GDx ECC using area under operating characteristic curves (AUCs), sensitivities at fixed specificities, and likelihood ratios (LRs). Results AUC of the average RNFL thickness of SDOCT to differentiate glaucoma from control eyes (0.868) was comparable (P ¼ 0.32) to that of GDx ECC (0.855). Sensitivity at 95% specificity was 63.2% for average RNFL thickness of SDOCT and 48.1% for the average RNFL measurement of GDx ECC. LRs of outside normal limits category of SDOCT parameters ranged between 5.6 and 7.7 while the same of GDx ECC parameters ranged between 3.1 and 3.7. LRs of within normal limits category of SDOCT parameters ranged between 0.18 and 0.24 while the same of GDx ECC parameters ranged between 0.20 and 0.32. Conclusion Though AUCs and sensitivities at fixed specificities were comparable between the RNFL parameters of SDOCT and GDx ECC in diagnosing glaucoma, LRs indicated that the RNFL parameters of SDOCT were better in 'ruling in' glaucoma.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.