Background: Hepatic iron content (HIC) is an important parameter for the management of iron overload. Non-invasive HIC assessment is often performed using biopsy-calibrated two-dimensional breath-hold Cartesian gradient echo (2D BH GRE) R 2 * -MRI. However, breath-holding is not possible in most pediatric patients or those with respiratory problems, and three-dimensional free-breathing radial GRE (3D FB rGRE) has emerged as a viable alternative. Purpose: To evaluate the performance of a 3D FB rGRE and validate its R 2 * and fat fraction (FF) quantification with 3D breath-hold Cartesian GRE (3D BH cGRE) and biopsy-calibrated 2D BH GRE across a wide range of HICs. Study Type: Retrospective. Subjects: Twenty-nine patients with hepatic iron overload (22 females, median age: 15 [5-25] years). Field Strength/Sequence: Three-dimensional radial and 2D and 3D Cartesian multi-echo GRE at 1.5 T. Assessment: R 2 * and FF maps were computed for 3D GREs using a multi-spectral fat model and 2D GRE R 2 * maps were calculated using a mono-exponential model. Mean R 2 * and FF values were calculated via whole-liver contouring and T 2 *thresholding by three operators. Statistical Tests: Inter-and intra-observer reproducibility was assessed using Bland-Altman and intraclass correlation coefficient (ICC). Linear regression and Bland-Altman analysis were performed to compare R 2 * and FF values among the three acquisitions. One-way repeated-measures ANOVA and Wilcoxon signed-rank tests, respectively, were used to test for significant differences between R 2 * and FF values obtained with different acquisitions. Statistical significance was assumed at P < 0.05. Results: The mean biases and ICC for inter-and intra-observer reproducibility were close to 0% and >0.99, respectively for both R 2 * and FF. The 3D FB rGRE R 2 * and FF values were not significantly different (P > 0.44) and highly correlated (R 2 ≥ 0.98) with breath-hold Cartesian GREs, with mean biases ≤ AE2.5% and slopes 0.90-1.12. In non-breath-holding patients, Cartesian GREs showed motion artifacts, whereas 3D FB rGRE exhibited only minimal streaking artifacts. Data Conclusion: Free-breathing 3D radial GRE is a viable alternative in non-breath-hold patients for accurate HIC estimation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.