• MR proton density fat fraction is highly reproducible at multiple levels. • Sciatic intraneural fat is positively correlated with increasing age (p < 0.05). • Positive correlations exist between bilateral sciatic nerve areas and age (p < 0.05). • Males had significantly higher sciatic intraneural fat than females (p < 0.05).
Purpose: To evaluate interreader performance in the measurement of the cross-sectional area and myosteatosis of pelvic skeletal muscles using fat quantification magnetic resonance imaging (MRI) and correlate with patient anthropomorphic characteristics. Materials and Methods: A Health Insurance Portability and Accountability Act–compliant retrospective cross-sectional study was performed. Between January and April 2016, 61 patients (26 males and 35 females) underwent a lumbosacral plexus 3T MRI with a modified three-dimensional spoiled gradient echo sequence dedicated to fat quantification (mDixon Quant; Philips Healthcare). Two independent reviewers outlined muscle cross-sectional area on axial images using a freehand region of interest tool and documented proton-density fat fraction (FF) and muscle area (cm 2 ) of the psoas, gluteus medius, gluteus maximus, and rectus femoris muscles on each side. Interreader agreement was assessed by intraclass correlation coefficient (ICC), and correlation between the measurements and subject's age, gender, and body mass index (BMI) was assessed using multiple linear regression analysis. Results: Excellent interreader agreement was obtained (ICC ≥0.74) for all muscle groups except for the left gluteus medius area and right psoas FF which showed good agreement (0.65 and 0.61, respectively). Statistically significant ( P ≤ 0.05) positive correlation was seen between the gluteal muscle FF and area with BMI, and rectus muscle FF with age and BMI. Statistically significant negative correlation between the rectus femoris area and age was also observed. Conclusion: Fat quantification MRI is a highly reproducible imaging technique for the assessment of myosteatosis and muscle size. Intramuscular FF and cross-sectional area were correlated with age and BMI across multiple muscle groups.
The utility of a semi-automatic method of measuring left ventricular (LV) volume geometrically from gated blood-pool studies and digital subtraction angiography (DSA) was investigated using computerized edge detection and spatial calibration algorithms. LAO LV volumes determined from gated blood-pool studies were compared to volumes obtained from contrast left ventriculograms in 21 patients and the applicability of this method to DSA was evaluated in 25 additional patients who also had conventional left ventriculography. There was excellent correlation between the two, both for radionuclide studies and for DSA. Computer-based geometric determinations of LV volume appear to be rapid, accurate, and less dependent on subjective operator decisions than previously reported geometric approaches.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.