SummaryAssessments of the vitamin K status in newborns and their mothers by means of des-γ-carboxy-prothrombin (PIVKA II) measurement have given equivocal results. Part of the variability could be attributed to differences in sensitivity (i.e. the ability to detect small concentrations) and validity (i.e. ability to detect vitamin K deficiency) of the methods applied. None of these methods have yet been validated with respect to plasma vitamin K1. In 22 healthy mother/infant pairs PIVKA II was determined using three different assays including ratio Xa/ecarin (Xa/ec), crossed immunoelectrophoresis (CIE), and an ELISA with a monoclonal antibody (MAB). The results were compared with conventional clotting tests and plasma vitamin K1. The following results were obtained:Cord blood: Clotting tests within age-related normal ranges; PIVKA II detection rates: 0/22 (Xa/ec), 1/22 (CIE), 4/22 (MAB); plasma vitamin K1: undetectable in 20/22.Mothers: Clotting tests all within normal range; PIVKA II detection rates: 1/22 (Xa/ec), 0/22 (CIE), 5/22 (MAB); plasma vitamin K1 (pg/ml) for all mothers (median; range): 186; 55–833; for PIVKA II positive mothers: 213; 59–699.PIVKA II detectability in newborns and mothers was not correlated. The results show an increase in sensitivity for PIVKA II detection in the order of MAB ≫CIE >Xa/ec. Due to the very low plasma vitamin K1 at birth, no correlation was possible between cord PIVKA II detectability and plasma vitamin K1. However, in mothers at term PIVKA II MAB appears to be unrelated to the vitamin K status.
We report the case of a woman who developed unexplained warfarin hypersensitivity after undergoing surgery to remove her ovaries. Presurgery, the patient's international normalised ratios (INR) control was stable and uneventful but 11 days after her operation she presented with extremely high (frequently ≥10) INR. Warfarin was discontinued on day 24 postoperation but 11 days later the plasma warfarin concentration was high at 4.8 mg/l (therapeutic range 0.7-2.3 mg/l). After cessation of warfarin, she required frequent doses of oral and intravenous vitamin K1 (totalling 48 mg) as well as two doses of prothrombin complex concentrate to normalise the INR. The patient was switched from warfarin to heparin, then to dabigatran with no further thrombosis or bleeding. While on heparin, the kinetics of warfarin elimination and vitamin K status were found to be normal and the reason for the onset of the extreme sensitivity to warfarin remains unknown.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.