The development of natural polymer-based scaffolds with excellent biocompatibility, antibacterial activity, and blood compatibility, able to facilitate full-thickness skin wound healing, remains challenging. In this study, we have developed three chitosan (CS)-based porous scaffolds, including CS, CS/CNT (carbon nanotubes), and CS/CNT/HA (nano-hydroxyapatite, n-HA) using a freeze-drying method. All three scaffolds have a high swelling ratio, excellent antibacterial activity, outstanding cytocompatibility, and blood compatibility in vitro. The introduction of CNTs exhibited an obvious increase in mechanical properties, and exerts excellent photothermal response, which displays excellent healing performance as a wound dressing in mouse full-thickness skin wound model when compared to CS scaffolds. CS/CNT/HA composite scaffolds present the strongest ability to promote full-thickness cutaneous wound closure and skin regeneration, which might be ascribed to the synergistic effect of photothermal response from CNT and excellent bioactivity from n-HA. Overall, the present study indicated that CNT and n-HA can be engineered as effective constituents in wound dressings to facilitate full-thickness skin regeneration.
ObjectiveThe intracranial venous system plays an important role in ensuring blood circulation and a stable blood supply to the fetal brain. In the present study, a cross-sectional area of the fetal straight sinus was quantitatively evaluated by fetal magnetic resonance imaging (MRI) to explore the method's clinical value.MethodsThe clinical and MRI data of 126 normal fetuses in mid-to-late stage pregnancies were retrospectively analyzed. The “dominant” sequence of the fetal straight sinus was selected, and the cross-sectional area of the lumen was measured at each gestational age to obtain the normal range at different ages and to analyze the developmental pattern and characteristics of the fetal straight sinus.ResultsThere were statistically significant differences in the cross-sectional area of the fetal straight sinus among different gestational ages (P < 0.05). The cross-sectional area of the fetal straight sinus was positively correlated with gestational age (coefficient of determination = 0.6892, P < 0.05). That is, the cross-sectional area of the fetal straight sinus grew with increasing gestational age, and the regression equation was y = 0.27 x – 2.14 (P < 0.05). Additionally, there were five fetuses with cerebral venous abnormalities, including four with heart failure and one with venous sinus thrombosis.ConclusionQuantitative measurement of a cross-sectional area of the fetal straight sinus by MRI enhanced understanding of the anatomical features and developmental pattern of fetal cerebral veins and provided a reference for the clinical diagnosis of related diseases and investigation concerning pathogenesis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.