Glucose homeostasis deficiency leads to a chronic increase in blood glucose concentration. In contrast to physiological glucose concentration, chronic superphysiological glucose concentration negatively affects a large number of organs and tissues. Glucose toxicity means a decrease in insulin secretion and an increase in insulin resistance due to chronic hyperglycemia. It is now generally accepted that glucose toxicity is involved in the worsening of diabetes by affecting the secretion of beta-cells. Several mechanisms have been proposed to explain the adverse effects of hyperglycemia. It was found that persistent hyperglycemia caused the functional decline of neutrophils. Infection is thus the main problem resulting from glucose toxicity in the acute phase. In other words, continued hyperglycemia is a life-threatening risk factor, not only in the chronic but also the acute phase, and it becomes a risk factor for infection, particularly in the perioperative period.
The Gyro centrifugal pump, PI (permanently implantable) series, is being developed as a totally implantable artificial heart. Our final goal is to establish a "functional TAH," a totally implantable biventricular assist system (BiVAS) with centrifugal pumps. A plastic prototype pump, Gyro PI 601, was evaluated through in vitro and in vivo studies as a single ventricular assist device (VAD). Based upon these results, the pump head material was converted to a titanium alloy, and the actuator was modified. These titanium Gyro pumps, PI 700 series, also were subjected to in vitro and in vivo studies. The Gyro PI 601 and PI 700 series have the same inner dimensions and characteristics, such as the eccentric inlet port, double pivot bearing system, secondary vane, and magnet coupling system; however, the material of the PI 700 is different from the PI 601. The Gyro PI series is driven by the Vienna DC brushless motor actuator. The inlet cannula of the right ventricular assist system (RVAS) specially made for this system consists of 2 parts: a hat-shaped silicone tip biolized with gelatin and an angled wire reinforced tube made of polyvinylchloride. The pump-actuator package was implanted into 8 calves in the preperitoneal space, bypassing from the left ventricle apex to the descending aorta for the left ventricular assist system (LVAS) and bypassing the right ventricle to the main pulmonary artery for the RVAS. According to the PI 601 feasibility protocol, 2 LVAS cases were terminated after 2 weeks, and 1 LVAS case and 1 RVAS were terminated after 1 month. The PI 700 series was implanted into 4 cases: 3 LVAS cases survived for a long term, 2 of them over 200 days (72-283 days), and 1 RVAS case survived for 1 month and was terminated according to the protocol for a short-term antithrombogenic screening and system feasibility study. Regarding power consumption, the plastic pump cases demonstrated from 6.2 to 12.1 W as LVAS and 7.3 W as RVAS, the titanium pump cases showed from 10.4 to 14.2 W as LVAS and 15.8 W as RVAS. All cases exhibited low hemolysis. The renal function and the liver function were maintained normally in all cases throughout these experimental periods. In the 2 RVAS cases, pulmonary function was normally maintained. No calves demonstrated thromboembolic signs or symptoms throughout the experiments except Case 1 with the plastic pump. However, in the plastic pump cases, bilateral renal infarction was suspected in 2 cases during necropsy whereas no abnormal findings were revealed in the titanium pump cases. There were also no blood clots inside the PI 700 series. As for the 601, the explanted pumps demonstrated slight thrombus formations at the top and bottom pivots except in 1 case. The Gyro PI series, especially the PI 700 series, demonstrated superior performance, biocompatibility, antithrombogenicity and low hemolysis. Also, the durability of the actuator was demonstrated. Based on these results, this titanium centrifugal pump is suitable as an implantable LVAS and RVAS. It is likely that the Gyro PI ...
Hemolysis remains one of the most serious problems during cardiopulmonary bypass (CPB), extracorporeal membrane oxygenation (ECMO), and percutaneous cardiopulmonary support (PCPS). However, the hemolytic characteristics associated with oxygenators are not well defined. A specialized hemolysis test protocol for oxygenators was developed. A comparative study was performed following this protocol to determine the hemolytic characteristics of the clinically available oxygenators during CPB; pressure drop measurements in the blood chamber were also performed. Four oxygenators (Medtronic Affinity, Cobe Optima, Terumo Capiox SX25, and Bard Quantum) were evaluated. Fresh blood from healthy Dexter calves anticoagulated with citrate phosphate dextrose adenine solution was used. The blood flow was fixed at 5 L/min, similar to that used in CPB. The Normalized Index of Hemolysis for Oxygenators (NIHO) has been modified according to the American Society of Testing and Materials (ASTM) standards. The NIH value, which was obtained from the circuit without an oxygenator, was subtracted from the primary NIH value, obtained from the circuit with an oxygenator to eliminate the effects of a centrifugal pump or other artifacts. The NIHO value was the lowest in the Affinity (0.0116 +/- 0.0017) and increased from Affinity < Optima (0.0270 +/- 0.0038) < Capiox (0.0335 +/- 0.0028) < Quantum (0.0416 +/- 0.0015 g/100 L). The Optima and Capiox did not demonstrate a significant difference. In addition, this NIHO value has a close relationship to the pressure drop. In conclusion, this new evaluation method is suitable to compare the biocompatibility performance of different types of clinically available oxygenators for CPB usage.
The Baylor Gyro permanently implantable centrifugal blood pump (Gyro PI pump) has been under development since 1995 at Baylor College of Medicine. Excellent results were achieved as a left ventricular assist device (LVAD) with survival up to 284 days. Based on these results, we are now focusing on the development of a biventricular assist device (BVAD) system, which requires 2 pumps to be implanted simultaneously in the preperitoneal space. Our hypothesis was that the Gyro PI pump would be an appropriate device for an implantable BVAD system. The Gyro PI 700 pump is fabricated from titanium alloy and has a 25 ml priming volume, pump weight of 204 g, height of 45 mm, and pump diameter of 65 mm. This pump can provide 5 L/min against 100 mm Hg at 2,000 rpm. In this study, 6 half-Dexter healthy calves have been used as the experimental model. The right pump was applied between the infundibular of the right ventricle and the main pulmonary artery. The left pump was applied between the apex of the left ventricle and the thoracic descending aorta. As for anticoagulation, heparin was administered at the first postoperative week and then converted to warfarin sodium from the second week after surgery. Both pump flow rates were controlled maintaining a pulmonary arterial flow of less than 160 ml/kg/min for the sake of avoidance of pulmonary congestion. Blood sampling was done to assess visceral organ function, and the data regarding pump performance were collected. After encountering the endpoint, which the study could not keep for any reasons, necropsy and histopathological examinations were performed. The first 2 cases were terminated within 1 week. Deterioration of the pump flow due to suction phenomenon was recognized in both cases. To avoid the suction phenomenon, a flexible conduit attached on the inlet conduit was designed and implanted. After using the flexible inflow conduit, the required power and the rotational speed were reduced. Furthermore, the suction phenomenon was not observed except for 1 case. There was no deterioration regarding visceral organ function, and pulmonary function was maintained within normal range except for 1 case. Even though the experimental animal survived up to 45 days with the flexible inflow conduit, an increase in power consumption due to thrombus formation behind the impeller became a problem. Lower rotational speed, which was probably produced by the effectiveness of the flexible inflow conduit, was speculated to be one of the reasons. And the minimum range of rotational speed was 1,950 rpm in these 6 BVAD cases and the previous 3 cases of LVAD. In conclusion, 6 cases of BVAD implantation were performed as in vivo animal studies and were observed up to 45 days. The flexible inflow conduit was applied in 4 of 6 cases, and it was effective in avoiding a suction phenomenon. The proper rotational speed of the Gyro PI 700 pump was detected from the viewpoint of antithrombogenicity, which is more than 1,950 rpm.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.