For these particular biphasic injection protocols, we have shown that image quality is comparable with a conventional protocol. This has been achieved by comparing enhanced densities of specific structures, as well as gestalt scoring by assessors, on a 256-slice MDCT.
Background Radiostereometric analysis (RSA) is the gold standard to measure early implant migration which is a predictive factor for implant survival. Purpose To validate an alternative computed tomography (CT) technique to measure implant migration in shoulder arthroplasty. Material and Methods A cadaver proximal humerus and a scapula, which had tantalum beads incorporated within them, were prepared to accept a short-stemmed humeral component and a two-pegged glenoid component of a commercial total shoulder arthroplasty (TSA) system. A five degree of freedom micrometer and goniometer equipped rig was used to translate and rotate the implant components relative to the respective bone to predetermined positions. Double CT examinations were performed for each position and CT motion analysis software (CTMA) was used to assess these movements. The accuracy and precision of the software was estimated using the rig’s micrometers and goniometers as the gold standard. The technique’s effective dose was also assessed. Results The accuracy was in the range of 0.07–0.23 mm in translation and 0.22–0.71° in rotation. The precision was in the range of 0.08–0.15 mm in translation and 0.23–0.54° in rotation. The mean effective dose for the CT scans was calculated to be 0.27 mSv. Conclusion In this experimental setting, accuracy, precision, and effective dose of the CTMA technique were found to be comparable to that of RSA. Therefore, we believe clinical studies are warranted to determine if CTMA is a suitable alternative to traditional RSA for migration measurements in TSA.
Multislice helical CT scanning has advantages of speed and X-ray tube loading, making it possible to image larger volumes in a single exposure. Our aim is to investigate dose implications for short scans from the additional X-ray tube rotations required to reconstruct a given volume in helical scanning. To this end a multislice scanner was compared with a single slice scanner. Two independent methods were used. The first was based on optical density measurements taken from a film exposed free-in-air as it moves with the CT bed along the scan axis. The second used measurements from a pencil ionization chamber supported free-in-air at the centre of the CT aperture for the duration of both a long scan and a short scan. This method assumes the same excess primary radiation at the extremes of both scans and the measurements are incorporated into two simultaneous equations. The dose-length product outside the imaged volume has been compared with the dose-length product inside the imaged volume using both methods. For 4 x 5 mm multislice collimation with a 360 degrees interpolation and a pitch of 0.875, the film and simultaneous equations methods show an excess dose-length product at the extremes of the scan volume equivalent to 3.3 cm and 3.5 cm extra scan length, respectively. This represents a large percentage of a short scan and is substantially greater than for a helical scan using the single slice scanner with 5 mm collimation, a 360 degrees interpolation and a pitch of 1. The latter showed an excess dose-length product at the extremes which was equivalent to 0.35 cm scan length by the film method and 0.25 cm using simultaneous equations. Taking the abdominal protocols recommended by the respective manufacturers, however, the multislice scanner could cover a 45 cm scan length in a single exposure, while the single slice scanner needed six exposures to image the same volume. With the multislice scanner set at 4 x 2.5 mm collimation, 360 degrees interpolation and a pitch of 0.875, the dose-length product outside the volume of interest was equivalent to 1.9 cm scan length by the first method and 1.8 cm using the second method. With 4 x 1 mm collimation it was equivalent to 1.0 cm using both methods. Changing the interpolation algorithm from 360 degrees to 180 degrees had no effect on the additional equivalent scan length while doubling the pitch resulted in a 25% increase. We conclude from this study that with the multislice scanner, the axial mode is to be preferred for short CT scans such as those used in patient biopsies and drainage. For paediatric helical scans shorter than 13 cm, dose length product is reduced by using 4 x 2.5 mm rather than 4 x 5 mm collimation. For longer scans, however, the increased CT dose index associated with narrower collimation in the multislice mode offsets the dose reduction at the extremes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.