Objective: Some drugs need processing before they can be administered or dispensed. We measured airborne exposure of pharmacy staff to small particles when performing these tasks. Methods: Reconstitution of powdered drugs in vials; crushing, splitting, and counting of tablets; and opening of capsules, using different ventilation strategies, were investigated in five pharmacies after in a worst-case approach. Airborne particulate matter was determined for a range of particles sizes. Results: Mean particle concentrations ranged from not detectable to 1.03 μg/m 3 (<1 μm) and 589.7 μg/m 3 (<10 μm). Dust exhaust made tasks safer. Most hazardous was pouring out tablets from a bulk supply, and least hazardous was reconstitution of a powder for injection. Conclusions: Occupational exposure during routine handling of drugs can occur, but the risks vary greatly with the nature and duration of the tasks.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.