To solve the 2 ? phase ambiguity for phase-resolved Doppler images in Doppler optical coherence tomography, we present a modified network programming technique for the first time to the best of our knowledge. The proposed method assumes that error of the discrete derivatives between unwrapped phase image and wrapped phase image can be arbitrary values instead of integer-multiple of 2 ? , which makes the real-phase restoration accurate and robust against noise. We compared our proposed method with the network programming method. Parameters including root-mean-square-error and noise amplification degree were adopted for comparison. The experimental study on simulated images, phantom, and real-vessel OCT images were performed. The proposed method consistently achieves optimal results.
Phase image in Fourier domain Doppler optical coherence tomography offers additional flow information of investigated samples, which provides valuable evidence towards accurate medical diagnosis. High quality phase images are thus desirable. We propose a noise reduction method for phase images by combining a synthetic noise estimation criteria based on local noise estimator (LNE) and distance median value (DMV) with anisotropic diffusion model. By identifying noise and signal pixels accurately and diffusing them with different coefficients respectively and adaptive iteration steps, we demonstrated the effectiveness of our proposed method in both phantom and mouse artery images. Comparison with other methods such as filtering method (mean, median filtering), wavelet method, probabilistic method and partial differential equation based methods in terms of peak signal-to-noise ratio (PSNR), equivalent number of looks (ENL) and contrast-to-noise ratio (CNR) showed the advantages of our method in reserving image energy and removing noise.
Real-time intraoperative optical coherence tomography (OCT) imaging of blood vessels after anastomosis operation can provide important information the vessel, such as patency, flow speed, and thrombosis morphology. Due to the strong scattering and absorption effect of blood, normal OCT imaging suffers from the problem of incomplete cross-sectional view of the vessel under investigation when the diameter is large. In this work, we present a novel cooperative three-view imaging spectral domain optical coherence tomography system for intraoperative exposed vascular imaging. Two more side views (left view and right view) were realized through a customized sample arm optical design and corresponding mechanical design and fabrication, which could generate cross-sectional images from three circumferential view directions to achieve a larger synthetic field of view (FOV). For each view, the imaging depth was 6.7 mm (in air) and the lateral scanning range was designed to be 3 mm. Therefore, a shared synthetic rectangle FOV of 3 mm × 3 mm was achieved through cooperative three view scanning. This multi-view imaging method can meet the circumferential imaging demands of vessels with an outer diameter less than 3 mm. Both phantom tube and rat vessel imaging confirmed the increased system FOV performance. We believe the intraoperative application of this cooperative three-imaging optical coherence tomography for objective vascular anastomosis evaluation can benefit patient outcomes in the future.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.