IMPORTANCEThere are limitations in current diagnostic testing approaches for Alzheimer disease (AD).OBJECTIVE To examine plasma tau phosphorylated at threonine 217 (P-tau217) as a diagnostic biomarker for AD.DESIGN, SETTING, AND PARTICIPANTS Three cross-sectional cohorts: an Arizona-based neuropathology cohort (cohort 1), including 34 participants with AD and 47 without AD (dates of enrollment, May 2007-January 2019); the Swedish BioFINDER-2 cohort (cohort 2), including cognitively unimpaired participants (n = 301) and clinically diagnosed patients with mild cognitive impairment (MCI) (n = 178), AD dementia (n = 121), and other neurodegenerative diseases (n = 99) (April 2017-September 2019); and a Colombian autosomal-dominant AD kindred (cohort 3), including 365 PSEN1 E280A mutation carriers and 257 mutation noncarriers (December 2013-February 2017).EXPOSURES Plasma P-tau217. MAIN OUTCOMES AND MEASURES Primary outcome was the discriminative accuracy of plasma P-tau217 for AD (clinical or neuropathological diagnosis). Secondary outcome was the association with tau pathology (determined using neuropathology or positron emission tomography [PET]).RESULTS Mean age was 83.5 (SD, 8.5) years in cohort 1, 69.1 (SD, 10.3) years in cohort 2, and 35.8 (SD, 10.7) years in cohort 3; 38% were women in cohort 1, 51% in cohort 2, and 57% in cohort 3. In cohort 1, antemortem plasma P-tau217 differentiated neuropathologically defined AD from non-AD (area under the curve [AUC], 0.89 [95% CI, 0.81-0.97]) with significantly higher accuracy than plasma P-tau181 and neurofilament light chain (NfL) (AUC range, 0.50-0.72; P < .05). The discriminative accuracy of plasma P-tau217 in cohort 2 for clinical AD dementia vs other neurodegenerative diseases (AUC, 0.96 [95% CI, 0.93-0.98]) was significantly higher than plasma P-tau181, plasma NfL, and MRI measures (AUC range, 0.50-0.81; P < .001) but not significantly different compared with cerebrospinal fluid (CSF) P-tau217, CSF P-tau181, and tau-PET (AUC range, 0.90-0.99; P > .15). In cohort 3, plasma P-tau217 levels were significantly greater among PSEN1 mutation carriers, compared with noncarriers, from approximately 25 years and older, which is 20 years prior to estimated onset of MCI among mutation carriers. Plasma P-tau217 levels correlated with tau tangles in participants with (Spearman ρ = 0.64; P < .001), but not without (Spearman ρ = 0.15; P = .33), β-amyloid plaques in cohort 1. In cohort 2, plasma P-tau217 discriminated abnormal vs normal tau-PET scans (AUC, 0.93 [95% CI, 0.91-0.96]) with significantly higher accuracy than plasma P-tau181, plasma NfL, CSF P-tau181, CSF Aβ42:Aβ40 ratio, and MRI measures (AUC range, 0.67-0.90; P < .05), but its performance was not significantly different compared with CSF P-tau217 (AUC, 0.96; P = .22).CONCLUSIONS AND RELEVANCE Among 1402 participants from 3 selected cohorts, plasma P-tau217 discriminated AD from other neurodegenerative diseases, with significantly higher accuracy than established plasma-and MRI-based biomarkers, and its performance wa...
IMPORTANCE The positron emission tomography (PET) tracer [ 18 F]flortaucipir allows in vivo quantification of paired helical filament tau, a core neuropathological feature of Alzheimer disease (AD), but its diagnostic utility is unclear. OBJECTIVE To examine the discriminative accuracy of [ 18 F]flortaucipir for AD vs non-AD neurodegenerative disorders. DESIGN, SETTING, AND PARTICIPANTS In this cross-sectional study, 719 participants were recruited from 3 dementia centers in South Korea, Sweden, and the United States between June 2014 and November 2017 (160 cognitively normal controls, 126 patients with mild cognitive impairment [MCI], of whom 65.9% were amyloid-β [Aβ] positive [ie, MCI due to AD], 179 patients with AD dementia, and 254 patients with various non-AD neurodegenerative disorders).EXPOSURES The index test was the [ 18 F]flortaucipir PET standardized uptake value ratio (SUVR) in 5 predefined regions of interest (ROIs). Cut points for tau positivity were determined using the mean +2 SDs observed in controls and Youden Index for the contrast AD dementia vs controls. MAIN OUTCOMES AND MEASURESThe reference standard was the clinical diagnosis determined at the specialized memory centers. In the primary analysis, the discriminative accuracy (ie, sensitivity and specificity) of [ 18 F]flortaucipir was examined for AD dementia vs all non-AD neurodegenerative disorders. In secondary analyses, the area under the curve (AUC) of [ 18 F]flortaucipir SUVR was compared with 3 established magnetic resonance imaging measures (hippocampal volumes and AD signature and whole-brain cortical thickness), and sensitivity and specificity of [ 18 F]flortaucipir in MCI due to AD vs non-AD neurodegenerative disorders were determined. RESULTS Among 719 participants, the overall mean (SD) age was 68.8 (9.2) years and 48.4% were male. The proportions of patients who were amyloid-β positive were 26.3%, 65.9%, 100%, and 23.8% among cognitively normal controls, patients with MCI, patients with AD dementia, and patients with non-AD neurodegenerative disorders, respectively. [ 18 F]flortaucipir uptake in the medial-basal and lateral temporal cortex showed 89.9% (95% CI, 84.6%-93.9%) sensitivity and 90.6% (95% CI, 86.3%-93.9%) specificity using the threshold based on controls (SUVR, 1.34), and 96.8% (95% CI, 92.0%-99.1%) sensitivity and 87.9% (95% CI, 81.9%-92.4%) specificity using the Youden Index-derived cutoff (SUVR, 1.27) for distinguishing AD dementia from all non-AD neurodegenerative disorders. The AUCs for all 5 [ 18 F]flortaucipir ROIs were higher (AUC range, 0.92-0.95) compared with the 3 volumetric MRI measures (AUC range, 0.63-0.75; all ROIs P < .001). Diagnostic performance of the 5 [ 18 F]flortaucipir ROIs were lower in MCI due to AD (AUC range, 0.75-0.84).CONCLUSIONS AND RELEVANCE Among patients with established diagnoses at a memory disorder clinic, [ 18 F]flortaucipir PET was able to discriminate AD from other neurodegenerative diseases. The accuracy and potential utility of this test in patient care require further rese...
Objectives To assess to what extent educational differences in total life expectancy (TLE) and disability-free life expectancy (DFLE) could be reduced by improving fruit and vegetable consumption in ten European countries. Methods Data from national census or registries with mortality follow-up, EU-SILC, and ESS were used in two scenarios to calculate the impact: the upward levelling scenario (exposure in low educated equals exposure in high educated) and the elimination scenario (no exposure in both groups). Results are estimated for men and women between ages 35 and 79 years. Results Varying by country, upward levelling reduced inequalities in DFLE by 0.1-1.1 years (1-10%) in males, and by 0.0-1.3 years (0-18%) in females. Eliminating exposure reduced inequalities in DFLE between 0.6 and 1.7 years for males (6-15%), and between 0.1 years and 1.8 years for females (3-20%). Conclusions Upward levelling of fruit and vegetable consumption would have a small, positive effect on both TLE and DFLE, and could potentially reduce inequalities in TLE and DFLE.
Increased cerebrospinal fluid neurofilament light (NfL) is a recognized biomarker for neurodegeneration that can also be assessed in blood. Here, we investigate plasma NfL as a marker of neurodegeneration in 13 neurodegenerative disorders, Down syndrome, depression and cognitively unimpaired controls from two multicenter cohorts: King’s College London (n = 805) and the Swedish BioFINDER study (n = 1,464). Plasma NfL was significantly increased in all cortical neurodegenerative disorders, amyotrophic lateral sclerosis and atypical parkinsonian disorders. We demonstrate that plasma NfL is clinically useful in identifying atypical parkinsonian disorders in patients with parkinsonism, dementia in individuals with Down syndrome, dementia among psychiatric disorders, and frontotemporal dementia in patients with cognitive impairment. Data-driven cut-offs highlighted the fundamental importance of age-related clinical cut-offs for disorders with a younger age of onset. Finally, plasma NfL performs best when applied to indicate no underlying neurodegeneration, with low false positives, in all age-related cut-offs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.