Purpose:To assess the apparent diffusion coefficient (ADC) value and diffusion tensor image (DTI) including fractional anisotropy (FA) of the noncancerous prostate and prostate cancer before and after carbon-ion radiotherapy (CIRT).
Materials and Methods:Nine patients with biopsy-proven prostate cancer underwent 1.5T magnetic resonance (MR) examinations. One patient with benign prostatic hypertrophy and one healthy volunteer were also examined as references. The changes in ADC values and DTI of the entire prostate calculated from b-values of 0 and 700 (s/mm 2 ) were estimated between before and after CIRT.Results: ADC values of prostate cancer significantly increased after CIRT by paired t-test (P Ͻ 0.01) but those of noncancerous inner gland (IG) and peripheral zone (PZ) showed no significant change. By analysis of variance, significant differences in ADC values were observed among prostate cancer and noncancerous IG and PZ before CIRT (P Ͻ 0.05). After CIRT, those significant differences had disappeared. FAs showed no significant differences in any comparisons. DTI showed changes in the direction of the main axis of the tensor in prostate cancer after CIRT.
Conclusion:There were changes in ADC and DTI in prostate cancer after CIRT. They may be useful for monitoring prostatic structural changes under radiotherapy.
BACKGROUND AND PURPOSE:Experiences with computer-assisted detection of cerebral aneurysms in diagnosis by radiologists in real-life clinical environments have not been reported. The purpose of this study was to evaluate the usefulness of computer-assisted detection in a routine reading environment.
Objective. To develop automatic visceral fat volume calculation software for computed tomography (CT) volume data and to evaluate its feasibility. Methods. A total of 24 sets of whole-body CT volume data and anthropometric measurements were obtained, with three sets for each of four BMI categories (under 20, 20 to 25, 25 to 30, and over 30) in both sexes. True visceral fat volumes were defined on the basis of manual segmentation of the whole-body CT volume data by an experienced radiologist. Software to automatically calculate visceral fat volumes was developed using a region segmentation technique based on morphological analysis with CT value threshold. Automatically calculated visceral fat volumes were evaluated in terms of the correlation coefficient with the true volumes and the error relative to the true volume.
Results. Automatic visceral fat volume calculation results of all 24 data sets were obtained successfully and the average calculation time was 252.7 seconds/case. The correlation coefficients between the true visceral fat volume and the automatically calculated visceral fat volume were over 0.999. Conclusions. The newly developed software is feasible for calculating visceral fat volumes in a reasonable time and was proved to have high accuracy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.