BACKGROUND Quantification and comparison of high-sensitivity (hs) cardiac troponin I (cTnI) and cTnT concentrations in chronic kidney disease (CKD) have not been reported. We examined the associations between hs cTnI and cTnT, cardiovascular disease, and renal function in outpatients with stable CKD. METHODS Outpatients (n = 148; 16.9% with prior myocardial infarction or coronary revascularization) with an estimated glomerular filtration rate (eGFR) of <60 mL · min−1 · (1.73 m2)−1 had serum cTnI (99th percentile of a healthy population = 9.0 ng/L), and cTnT (99th percentile = 14 ng/L) measured with hs assays. Left ventricular ejection fraction (LVEF) and mass were assessed by echocardiography, and coronary artery calcification (CAC) was determined by computed tomography. Renal function was estimated by eGFR and urine albumin/creatinine ratio (UACR). RESULTS The median (interquartile range) concentrations of cTnI and cTnT were 6.3 (3.4–14.4) ng/L and 17.0 (11.2–31.4) ng/L, respectively; 38% and 68% of patients had a cTnI and cTnT above the 99th percentile, respectively. The median CAC score was 80.8 (0.7–308.6), LV mass index was 85 (73–99) g/m2, and LVEF was 58% (57%–61%). The prevalences of prior coronary disease events, CAC score, and LV mass index were higher with increasing concentrations from both hs cardiac troponin assays (P < 0.05 for all). After adjustment for demographics and risk factors, neither cardiac troponin assay was associated with CAC, but both remained associated with LV mass index as well as eGFR and UACR. CONCLUSIONS Increased hs cTnI and cTnT concentrations are common in outpatients with stable CKD and are influenced by both underlying cardiac and renal disease.
Background: The ability of the N-terminal region of human albumin to bind cobalt is diminished by myocardial ischemia. The characteristics of an assay based on albumin cobalt binding were assessed in suspected acute coronary syndrome patients and in a control reference population. The ability of the Albumin Cobalt Binding (ACBTM) Test measurement at presentation to predict troponin-positive or -negative results 6–24 h later was also examined. Methods: We enrolled 256 acute coronary syndrome patients at four medical centers. Blood specimens were collected at presentation and then 6–24 h later. The dichotomous decision limit and performance characteristics of the ACB Test for predicting troponin-positive or -negative status 6 h-24 h later were determined using ROC curve analysis. Results for 32 patients could not be used because the time of onset of ischemia appeared to have been >3 h before presentation or was uncertain. The reference interval was determined by parametric analysis to estimate the upper 95th percentile of a reference population (n = 109) of ostensibly healthy individuals. Results: Increased cTnI was found in 35 of 224 patients. The ROC curve area for the ACB Test was 0.78 [95% confidence interval (CI), 0.70–0.86]. At the optimum decision point of 75 units/mL, the sensitivity and specificity of the ACB Test were 83% (95% CI, 66–93%) and 69% (95% CI, 62–76%). The negative predictive value was 96% (95% CI, 91–98%), and the positive predictive value was 33% (95% CI, 24–44%). The within-run CV of the ACB Test was 7.3%. Results for the reference population were normally distributed; the one-sided parametric 95th percentile was 80.2 units/mL. Conclusions: This exploratory study suggests that the ACB Test has high negative predictive value and sensitivity in the presentation sample for predicting troponin-negative or -positive results 6–24 h later.
Many new technologies are being applied to measure blood glucose concentrations, but there is a lack of a standardized approach to evaluate performance of these devices. We sought to identify the key elements in evaluating the performance of devices for measuring blood glucose. We examined these elements in a multicenter study of four brands of glucose meters that are commonly used by diabetic patients. We tested control materials, spiked whole blood specimens, and 461 heparinized whole blood specimens in triplicate by each of the four brand glucose meters, and analyzed the plasma glucose concentrations of these specimens by a hexokinase (HK) method that incorporated reference materials developed by National Institute of Standards and Technology. Testing with glucose meters was performed at three sites, with multiple operators, meters, and representative lots of reagents. We evaluated the systematic bias, random error, and clinical significance of glucose meters. Meters were precise with a coefficient of variation of <4% across a wide range of glucose concentrations. Slopes significantly different from 1.0 were observed for two meters with 11-13% and -11% to -13% at the 95% confidence interval level by the linear regression of meter results versus the HK method from 33 to 481 mg/dL (correlation coefficient >0.98 and standard error of estimation S(y/x) <13 mg/dL for both meters). Analysis of the clinical significance of bias by Clarke Error Grid showed that results of the four meters were outside the accurate zone (26.5%, 2.4%, 1.5%, and 5.6%). Only a small number of the results showed clinically significant bias, mostly in the hypoglycemic range. Meters performed consistently throughout the study and, generally, were precise, although precision varied at extremely high or low glucose concentrations. Two of the glucose meters had substantial systematic bias when compared with an HK method, indicating a need for improving calibration and standardization. Analytical performance varied over the physiological range of glucose values so that separate accuracy and precision goals should be defined for hypoglycemic, normoglycemic, and hyperglycemic ranges. This study describes the current state of performance of blood glucose monitoring devices and points out those factors that should be assessed during evaluation of new devices.
Background How to select healthy reference subjects in deriving 99th percentiles for cardiac troponin assays still needs to be clarified. To assist with global implementation of high sensitivity (hs)-cardiac troponin (cTn) I and hs-cTnT assays in clinical practice, we determined overall and sex-specific 99th percentiles in 9 hs-cTnI and 3 hs-cTnT assays using a universal sample bank (USB). Methods The Universal Sample Bank (USB) comprised healthy subjects, 426 men and 417 women, screened using a health questionnaire. Hemoglobin A1c (>URL 6.5%), NT-proBNP (>URL 125 ng/L) and eGFR (<60 mL/min), were used as surrogate biomarker exclusion criteria along with statin use. 99th percentiles were determined by nonparametric, Harrell--Davis bootstrap, and robust methods. Results Subjects were ages 19 to 91 years, Caucasian 58%, African American 27%, Pacific Islander/Asian 11%, other 4%, Hispanic 8%, and non-Hispanic 92%. The overall and sex-specific 99th percentiles for all assays, before and after exclusions (n = 694), were influenced by the statistical method used, with substantial differences noted between and within both hs-cTnI and hs-cTnT assays. Men had higher 99th percentiles (ng/L) than women. The Roche cTnT and Beckman and Abbott cTnI assays (after exclusions) did not measure cTn values at ≥ the limit of detection in ≥50% women. Conclusions Our findings have important clinical implications in that sex-specific 99th percentiles varied according to the statistical method and hs-cTn assay used, not all assays provided a high enough percentage of measurable concentrations in women to qualify as a hs-assay, and the surrogate exclusion criteria used to define normality tended to lower the 99th percentiles.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.