To evaluate all simulation models for ophthalmology technical and non-technical skills training and the strength of evidence to support their validity and effectiveness. A systematic search was performed using PubMed and Embase for studies published from inception to 01/07/2019. Studies were analysed according to the training modality: virtual reality; wet-lab; dry-lab models; e-learning. The educational impact of studies was evaluated using Messick’s validity framework and McGaghie’s model of translational outcomes for evaluating effectiveness. One hundred and thirty-one studies were included in this review, with 93 different simulators described. Fifty-three studies were based on virtual reality tools; 47 on wet-lab models; 26 on dry-lab models; 5 on e-learning. Only two studies provided evidence for all five sources of validity assessment. Models with the strongest validity evidence were the Eyesi Surgical, Eyesi Direct Ophthalmoscope and Eye Surgical Skills Assessment Test. Effectiveness ratings for simulator models were mostly limited to level 2 (contained effects) with the exception of the Sophocle vitreoretinal surgery simulator, which was shown at level 3 (downstream effects), and the Eyesi at level 5 (target effects) for cataract surgery. A wide range of models have been described but only the Eyesi has undergone comprehensive investigation. The main weakness is in the poor quality of study design, with a predominance of descriptive reports showing limited validity evidence and few studies investigating the effects of simulation training on patient outcomes. More robust research is needed to enable effective implementation of simulation tools into current training curriculums.
Conjunctival naevi are one of the most common lesions affecting the conjunctiva. While benign in the vast majority of cases, the risk of malignant transformation necessitates regular follow-up. They are well known to increase in size; however, we present the first photo-documented case of spontaneous regression of conjunctival naevus. In most cases, surgical excision is performed due to the clinician's concerns over malignancy. However, a substantial proportion of patients request excision. Highlighting the potential for regression of the lesion is important to ensure patients make an informed decision when contemplating such surgery.
BackgroundWith increasing availability of toric intraocular lenses (IOL) for cataract surgery, real-world refractive outcome data is needed to aid the counselling of patients regarding lens choice. We aim to assess the outcomes of toric intraocular lens use in the non-specialist environment of a typical United Kingdom NHS cataract service.MethodsA retrospective cohort study conducted at the Oxford Eye Hospital, Oxford University Hospitals NHS Foundation Trust, UK. All patients who received a toric IOL implant over a 10 months period. Patients underwent pre-operative corneal marking, phacoemulsification and toric IOL implantation. Biometry was obtained using a Zeiss IOLMaster 500 and the toric IOLs were selected using the manufacturers’ online calculators. Post-operative refractions were obtained from optometrist’s manifest refraction or by autorefraction. The outcome measures were post-operative unaided visual acuity (UVA), spherical equivalent refraction, cylindrical correction and all complications.ResultsThirty-two eyes of 24 patients aged 21–86 years (mean 66.4, SD 14.5) were included. UVA was superior to pre-operative best-corrected visual acuity (BCVA) in 81% of eyes, same in 16% and inferior in 3%, resulting in a median improvement of 0.20 LogMAR (IQR 0.10 to 0.30). 56%, 81%, 94% and 100% of eyes were within ±0.5, ±1.0, ±1.5 and ±2.0 D of predicted spherical equivalent, respectively. Three (9%) eyes required further surgery to rectify significant IOL rotation.ConclusionsReduced cylindrical correction and improved UVA could be expected in the majority of patients undergoing toric IOL implantation. Patients should be counselled about the risk of lens rotation.
An 81-year-old man was taken to Accident & Emergency after a fall. CT brain imaging demonstrated a well-defined, homogenous, hyperdense mass in the posterior segment of the left eye. Reported as vitreous haemorrhage, an urgent ophthalmological assessment was instigated.Detailed history revealed previous vitreoretinal procedures for multiple retinal detachments. Ophthalmological examination confirmed presence of silicone oil in this eye.The appearance of silicone oil in the eye has become an increasingly prevalent finding given its continued use in complex vitreoretinal procedures since 1962. Clinicians regularly interpreting orbital, facial and brain imaging need to be aware of these imaging appearances to prevent diagnostic confusion.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.