Background:Short implants are manufactured for use in atrophic regions of the jaws. Although many studies report on short implants as ≤10 mm length with considerable success, the literature regarding survival rate of ≤7 mm is sparse.Purpose:The purpose of this study was to systematically evaluate the publications concerning short dental implants defined as an implant with a length of ≤7 mm placed in the maxilla or in the mandible.Materials and Methods:A Medline and manual search was conducted to identify studies concerning short dental implants of length ≤7 mm published between 1991 and 2011. The articles included in this study report data on implant length ≤7 mm, such as demographic variables, implant type, location in jaws, observation time, prostheses and complications.Results:The 28 included studies represent one randomized controlled trial, 12 prospective studies and 10 retrospective studies. The survival rate of short implant was found to be increased from 80% to 90% gradually, with recent articles showing 100%.Conclusion:When severe atrophy of jaws was encountered, short and wide implants can be placed successfully.
Excessive gingival display is a frequent finding that can occur because of various intraoral or extraoral etiologies. This report describes the use of surgical lip repositioning technique for the management of a gummy smile associated with vertical maxillary excess and hypermobility of the upper lip. The procedure restricts the muscle pull of the elevator lip muscles by shortening the vestibule, thus reducing the gingival display when smiling. Healing was uneventful and follow-up examinations of 10 months revealed reduced gingival display. For patients desiring a less invasive alternative to orthognathic surgery, lip repositioning is a viable alternative.
The results showed possible changes in the cellular and molecular components of peripheral blood in patients with GAP compared to periodontally-healthy controls. These changes might represent the contribution of periodontal infections to systemic inflammation in relatively young individuals.
Aim:The aim of the study is to evaluate the influence implant length on stress distribution at bone implant interface in single immediately loaded implants when placed in D4 bone quality.Materials and Methods:A 2-dimensional finite element models were developed to simulate two types of implant designs, standard 3.75 mm–diameter tapered body implants of 6 and 10 mm lengths. The implants were placed in D4 bone quality with a cortical bone thickness of 0.5 mm. The implant design incorporated microthreads at the crestal part and the rest of the implant body incorporated Acme threads. The Acme thread form has a 29° thread angle with a thread height half of the pitch; the apex and valley are flat. A 100 N of force was applied vertically and in the oblique direction (at an angle of 45°) to the long axis of the implants. The respective material properties were assigned. Micro-movements and stresses at the bone implant interface were evaluated.Results:The results of total deformation (micro-movement) and Von mises stress were found to be lower for tapered long implant (10 mm) than short implant (6 mm) while using both vertical as well as oblique loading.Conclusion:Short implants can be successfully placed in poor bone quality under immediate loading protocol. The novel approach of the combination of microthreads at the crestal portion and acme threads for body portion of implant fixture gave promising results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.