Conventional C-arm image intensifiers (CCA) are an essential and indispensable aid in modern orthopaedic surgery. CCAs are defaulted to auto-pulse mode which emit multiple pulses (or bursts) of radiation to obtain optimum image quality. The number of pulses per shot can be configured manually. The purpose of this study is to investigate the efficacy of the single pulse mode of CCA in reducing and fixing paediatric supracondylar humeral fractures (SCHF). A retrospective chart review of 99 paediatric patients who underwent closed reduction and percutaneous pinning of displaced SCHF was performed. Fifty-one consecutive cases operated with auto-pulse mode (group A). Another 48 consecutive cases were operated with the singlepulse mode (group B). Baumann's angle, operative duration and average radiation dose rate were recorded for comparison between both groups. Twenty postpinning images were randomly selected (10 from each group) to study intra-and interobserver reliability. Twelve doctors were recruited and tasked to identify if each X-ray was taken with the autopulse or single-pulse mode. This was repeated after 2 weeks. The patients in the auto-pulse mode group had a significantly higher mean radiation dose of 40.4 ± 32.51 cGycm 2 /min compared to that of 14.8 ± 3.24 cGycm 2 /min for the single-pulse group (P ≤ 0.001). All patients in both groups had Baumann's angle within normal range of 64-81°. No significant difference was noted in average intraoperative timings between both groups (P = 0.869). In the majority of cases, the doctors were unable to visually differentiate between the modes of CCA used. The single-pulse mode is an excellent alternative to the auto-pulse mode in fixing SCHF. It gives significantly lower radiation without compromising the surgical outcome.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.