A compact 1.5 microm all-fiber pulsed coherent Doppler lidar system for wind sensing, which includes the functions of variable pulse width and automatic polarization control has been developed. The system configuration is introduced and key components used in the system are explained. Theoretical performances of the system in wind sensing are estimated and compared with experimental results. The measurable range corresponding to the detection probability of >80% is approximately 1 km or more in the case of 150 m range resolution under the normal atmospheric conditions.
We have demonstrated the 1.6 mum cw modulation hard-target differential absorption lidar system for CO(2) sensing. In this system, ON and OFF wavelength laser lights are intensity modulated with cw signals. Received lights of the two wavelengths from the hard target are discriminated by modulation frequencies in the electrical signal domain. The optical circuit is fiber based, and this makes the system compact and reliable. It is shown that a stable CO(2) concentration measurement corresponding to a fluctuation of 4 ppm (rms) (ppm is parts per million) has been achieved in 32 s measurement intervals and the 1 km path.
In a previous study, we developed a 1.6 μm continuous-wave (cw) modulation laser absorption spectrometer system for CO(2) sensing and demonstrated the measurement of small fluctuations in CO(2) corresponding to a precision of 4 parts per million (ppm) with a measurement interval of 32 s. In this paper, we present the process to achieve this highly specific measurement by introducing important points, which have not been shown in the previous study. Following the results of preliminary experiments, we added a function for speckle averaging on the optical antenna unit. We additionally came up with some ideas to avoid the influences of etalon effects and polarization dependence in optical components. Because of the new functions, we realized a calibration precision of 0.006 dB (rms), which corresponds to a CO(2) concentration precision of less than 1 ppm for a 2 km path. We also analyzed the CO(2) sensing performance after the improvements described above. The measured short time fluctuation of the differential absorption optical depth was reasonably close to that calculated using the carrier-to-noise ratio of the received signal.
A feasibility study is carried out on a 1.6 μm continuous-wave modulation laser absorption spectrometer system for measurement of global CO(2)concentration from a satellite. The studies are performed for wavelength selection and both systematic and random error analyses. The systematic error in the differential absorption optical depth (DAOD) is mainly caused by the temperature estimation error, surface pressure estimation error, altitude estimation error, and ON wavelength instability. The systematic errors caused by unwanted backscattering from background aerosols and dust aerosols can be reduced to less than 0.26% by using a modulation frequency of around 200 kHz, when backscatter coefficients of these unwanted backscattering have a simple profile on altitude. The influence of backscattering from cirrus clouds is much larger than that of dust aerosols. The transmission power required to reduce the random error in the DAOD to 0.26% is determined by the signal-to-noise ratio and the carrier-to-noise ratio calculations. For a satellite altitude of 400 km and receiving aperture diameter of 1 m, the required transmission power is approximately 18 W and 70 W when albedo is 0.31 and 0.08, respectively; the total measurement time in this case is 4 s, which corresponds to a horizontal resolution of 28 km.
, "Underwater three-dimensional imaging laser sensor with 120-deg wide-scanning angle using the combination of a dome lens and coaxial optics," Opt. Eng. Abstract. We developed an underwater three-dimensional (3-D) imaging sensor using a 532-nm laser. The sensor system combines a dome lens with coaxial optics to realize a wide-scanning angle of 120 deg ðhorizontalÞ × 30 deg ðverticalÞ while having a compact size of 25-cm diameter and 60-cm length. A detector sensitivity time control circuit and a time-to-digital converter are used to detect a small signal and suppress the unwanted backscattered signals due to marine snow. 3-D imaging of the seafloor with 20-m width and 60-m length was demonstrated in the sea around Ishigaki Island, Japan.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.