Background: Various clinical trials provide evidence about the safety, effectiveness, and therapeutic success of percutaneous left atrial appendage closure (LAAC) using various occlusion devices. These devices are foreign materials implanted into the left atrium and may deteriorate left atrial (LA) function. The aim of this study was to evaluate the change in transesophageal echocardiography (TEE)-derived LA strain after LAAC. Methods and Results: The study included 95 patients (age: 75 ± 6.7 years, 67% male) who underwent percutaneous LAAC. LA strain was evaluated at three different time intervals by TEE (baseline, 45 days, and 180 days after the procedure). All data were analyzed using the software Image-Arena (TomTec ® ). Seventy patients had atrial fibrillation, whereas 25 were in sinus rhythm at baseline and during follow-up. Analysis was performed for peak atrial longitudinal strain (PALS) and peak atrial contraction strain (PACS) from segments of the lateral wall in mid-esophageal four-chamber view. PACS was obtained in patients with sinus rhythm during examinations. Compared to baseline, PALS increased at 45 days after the procedure (12.4% ± 8.4% at baseline vs. 16.0% ± 10.6% after 45 days, P = 0.001) and remained stable from 45 days to 180 days after procedure (13.8% ± 9.1% after 45 days vs. 17.2% ± 12.6% after 180 days, P = 0.092). Similarly, PACS increased at 45 days after the procedure (5.8% ± 3.9% at baseline vs. 10.6% ± 7.6% after 45 days, P = 0.001) and remained stable from 45 days to 180 days after the procedure (7.6% ± 4.5% after 45 days vs. 7.9% ± 3.1% after 180 days, P = 0.876). Conclusions: Our study demonstrated for the first time the improvement in TEE-derived LA strain following LAAC within 45 days of implantation. The findings suggest improved LA function following LAAC.
(1) Background: The assessment of residual peri-device leakages (PDL) after left atrial appendage occlusion (LAAO) remains crucial for post-procedural management. Our study aimed to verify a novel echocardiographic classification for the prediction of PDL. (2) Methods: Echocardiographic data of 72 patients who underwent percutaneous LAAO were evaluated. All echo images were analyzed by two independent investigators using standard analysis software (Image-Arena IA-4.6.4.44 by TomTec®, Munich, Germany). A total number of 127 studies was evaluated. Forty-four patients had baseline studies, at 45 days and at 6 months post-implantation. We propose a morphological classification of LAA devices based on the amount of echodensity inside the devices into three types: type A showing complete homogenous thrombosis, type B incompletely thrombosed device with inhomogeneous echo-free space <50% of device, and type C with partially thrombosed device in which the echo free space was >50% of device in various planes, which we called the “ice-cream cone” sign. Each type was matched to the degree of PDL and clinical outcome parameters. (3) Results: Patients with type C had the highest percentage of PDL at 45 days follow-up (type A: 24%, type B: 31%, type C 100% PDL, p < 0.001) and at 6 months follow-up (type A: 7%, type B: 33%, type C 100% PDL, p < 0.001). Notably, device size in patients with PDL was larger than that in patients without PDL at 6 months follow-up (25.6 ± 3.5 mm vs. 28.7 ± 3.4 mm, p = 0.004). Device size in patients with type C appearance was the largest of the three types (type A: 25.9 ± 3.6 mm, type B: 25.8 ± 3.4 mm, type C 29.8 ± 3.0 mm, type A vs. C; p = 0.019; type B vs. C, p = 0.007). (4) Conclusions: In conclusion, PDL are common post-LAAO, and their frequency is underestimated and under-recognized. PDL are much more common in patients with larger LAA ostial sizes and likely lower longitudinal compression. Type C appearance of the LAAO devices (“ice-cream cone sign”) has a high positive predictive value for PDL. Further studies are needed for better delineation of the clinical importance of this proposed classification.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.