Acoustic and electrical characteristics of biological tissue are important factors in magnetoacoustic tomography with magnetic induction (MAT-MI). Acoustic inhomogeneity significantly affects the propagations of sound waves. Differences in sound speed lead to distortions of the sound sources in the reconstruction process. The objective of this study is to develop a novel algorithm to reconstruct the sound source distribution in an acoustically inhomogeneous medium. The proposed algorithm is developed on the basis of the finite-difference time-domain method and time-reversal acoustic theory; it combines the relationship among symmetrical transducers with the back-projection algorithm. An acoustically inhomogeneous model with different regions of variable sound speeds is established to validate the proposed algorithm. From the data collected by a rotated focused transducer, first, the sound speed distribution is reconstructed, and then, the sound sources of the model are reconstructed. The reconstructed sound sources are obviously distorted when the speed differences are not considered. In contrast, the proposed algorithm yields reconstructed sound sources that are consistent with the model in terms of shape and size. Thus, the proposed algorithm is capable of accurately reconstructing the acoustic sources distribution in an acoustically inhomogeneous medium. This method provides a solution reducing the influence of acoustic inhomogeneity in MAT-MI. The distributions of sound speed can be obtained during the process of reconstructing the sound source. Consequently, the imaging of the acoustic speed and the electrical conductivity of biological tissues can be implemented simultaneously in MAT-MI.
Both electrical properties and biomarkers of biological tissues can be used to distinguish between normal and diseased tissues, and the correlations between them are critical for clinical applications of conductivity (σ) and permittivity (ε); however, these correlations remain unknown. This study aimed to investigate potential correlations between electrical characteristics and biomarkers of breast cancer cells (BCC). Changes in σ and ε of different components in suspensions of normal cells and BCC were analyzed in the range of 200 kHz–5 MHz. Pearson's correlation coefficient heatmap was used to investigate the correlation between σ and ε of the cell suspensions at different stages and biomarkers of cell growth and microenvironment. σ and ε of the cell suspensions closely resembled those of tissues. Further, the correlations between Na+/H+ exchanger 1 and ε and σ of cell suspensions were extremely significant among all biomarkers (pε < 0.001; pσ < 0.001). There were significant positive correlations between cell proliferation biomarkers and ε and σ of cell suspensions (pε/σ < 0.05). The microenvironment may be crucial in the testing of cellular electrical properties. ε and σ are potential parameters to characterize the development of breast cancer.
BackgroundMagneto-acoustic tomography with current injection involves using electrical impedance imaging technology. To explore the potential applications in imaging biological tissue and enhance image quality, a new scan mode for the transducer is proposed that is based on translational and circular scanning to record acoustic signals from sources.MethodsAn imaging algorithm to analyze these signals is developed in respect to this alternative scanning scheme. Numerical simulations and physical experiments were conducted to evaluate the effectiveness of this scheme. An experiment using a graphite sheet as a tissue-mimicking phantom medium was conducted to verify simulation results. A pulsed voltage signal was applied across the sample, and acoustic signals were recorded as the transducer performed stepped translational or circular scans. The imaging algorithm was used to obtain an acoustic-source image based on the signals.ResultsIn simulations, the acoustic-source image is correlated with the conductivity at the sample boundaries of the sample, but image results change depending on distance and angular aspect of the transducer. In general, as angle and distance decreases, the image quality improves. Moreover, experimental data confirmed the correlation.ConclusionThe acoustic-source images resulting from the alternative scanning mode has yielded the outline of a phantom medium. This scan mode enables improvements to be made in the sensitivity of the detecting unit and a change to a transducer array that would improve the efficiency and accuracy of acoustic-source images.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.