Objective To compare the efficacy and safety of aspirin with rivaroxaban following treatment with enoxaparin for prevention of venous thromboembolism (VTE) after hip fracture surgery (HFS). Methods A total of 390 patients were enrolled in the trial. According to an odd or even number at the end of their registration number, the patients were divided into the aspirin group (n = 198) and the rivaroxaban group (n = 192). All patients were given enoxaparin subcutaneous injection after the operation and returned to the routine dose the next day until postoperative day five. The patients in the aspirin group received an additional 16 days of thromboprophylaxis with 100 mg of aspirin once daily. The rivaroxaban group was assigned to receive an additional 16 days of thromboprophylaxis with 10 mg of oral rivaroxaban once daily. Patients were followed for 90 days regarding VTE and bleeding complications. Results The incidence of VTE in the aspirin group and rivaroxaban group was 6.6% (13/198) and 5.7% (11/192), respectively (P = 0.83). The rate of major bleeding events occurred in two (1.0%) patients in the aspirin group and in one patient (0.5%) in the rivaroxaban group (P = 1.0). A combination of major bleeding and clinically relevant nonmajor bleeding occurred in five patients (2.5%) in the aspirin group and in six patients (3.1%) in the rivaroxaban group (P = 0.77). During the 90‐day follow‐up, a pulmonary embolism developed in one patient (0.5%) in the aspirin group and none in the rivaroxaban group (P = 1.0). Conclusions Extended prophylaxis for 21 days with aspirin was equivalent to the direct oral anticoagulant rivaroxaban after hip fracture surgery with an initial 5‐day postoperative course of enoxaparin. Aspirin may be an effective, safe, convenient, and cheap alternative for extended prophylaxis after hip fracture surgery.
Long non-coding RNA (LncRNA) brain-derived neurotrophic factor antisense (BDNF-AS) has been found to be down-regulated and function in a tumor suppressive role in human cancers. However, the expression status and function of BDNF-AS is still unknown in osteosarcoma (OS). In our study, BDNF-AS expression was found to be decreased in OS tissues and cells. Moreover, BDNF-AS low expression was correlated with advanced Enneking stage, large tumor size and poor prognosis in OS patients. The multivariate analysis suggested low expression of BDNF-AS was an independent unfavorable prognostic factor for overall survival in OS patients. The in vitro studies indicated that BDNF-AS overexpression inhibits OS cell proliferation and promotes cell apoptosis through regulating cleaved caspase-3. In conclusion, BDNF-AS serves as a tumor suppressive lncRNA in OS.
PurposeTo access serum parathyroid hormone (PTH) level in elderly patients with hip fracture in relation to fracture healing outcomes.MethodsThis study included 90 elderly male patients with hip fracture and they were defined as the hip fracture group, and they were divided into healing effective group and delayed healing group by final fracture healing outcomes, 45 cases in each group; another 45 male patients older than 70 years without established osteoporosis and hip fracture were included as the control group. The levels of serum PTH level were examined in each group.ResultsSerum PTH level was significantly higher in healing effective group patients at the 7 days and 14 days after fracture than the delayed healing patients.ConclusionsOur results show that serum PTH level may be an effective indicator of hip fracture delayed healing risk in the elderly.
BackgroundLimb length discrepancy (LLD) is one of the most common postoperative complications and can cause serious consequences. Poor recovery of femoral offset (OD) will result in weakness of the patient's external rotator muscles and affect the patient's postoperative function. The study is aimed to present a simple approach that compensates for the shortcomings of previous measuring devices and combines the advantages of different measuring devices to provide more accurate limb length and femoral offset restoration in total hip arthroplasty (THA).MethodsThis study was a prospective controlled trial involving 89 patients with THA. Group I (n = 44) was used for intraoperative measurement of THA with our self-designed horizontal calibrator. Group II (n = 45) was measured by a traditional freehand technique. The main outcome indicators were measured on the Neusoft PACS, including LLD, femoral offset deviation, and operative time. IBM SPSS 23.0 was used for data analysis.ResultsThe independent sample t-test was performed for all the data. The operative time, preoperative radiographic LLD, and OD of Group I and Group II had no statistical significance. Postoperative LLD of Group I and Group II were 2.5 ± 2.1 mm (range −5.7 to 8.3 mm) and 6.2 ± 4.3 mm (range −18.0 to 15.2 mm), and the independent sample t-test data of both (P < 0.001; 95%CI = −5.1, −2.2) showed statistical significance. In Group I, there were 38 THAs with LLD <5 mm, accounting for 86% and there were 44 THAs with LLD <10 mm, accounting for 100%. In Group II, there were 20 THAs with LLD <5 mm, accounting for 44%. There were 36 THAs with LLD <10 mm, covering for 80%. There was no significant difference in postoperative femoral offset and OD.ConclusionThe horizontal calibrator can provide more accurate limb length and femoral offset recovery in THA. It is a simple surgical technique that does not add additionally surgical costs and does not significantly increase operative time, providing a new solution for surgeons to resolve postoperative LLD and restore femoral offset.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.