ObjectivesThe aim of our scoping review was to identify and summarize current evidence on the biomechanics of fencing to inform athlete development and injury prevention.DesignScoping review.MethodPeer-reviewed research was identified from electronic databases using a structured keyword search. Details regarding experimental design, study group characteristics and measured outcomes were extracted from retrieved studies, summarized and information regrouped under themes for analysis. The methodological quality of the evidence was evaluated.ResultsThirty-seven peer-reviewed studies were retrieved, the majority being observational studies conducted with experienced and elite athletes. The methodological quality of the evidence was “fair” due to the limited scope of research. Male fencers were the prevalent group studied, with the lunge and use of a foil weapon being the principal movement evaluated. Motion capture and pedabarography were the most frequently used data collection techniques.ConclusionsElite fencers exhibited sequential coordination of upper and lower limb movements with coherent patterns of muscle activation, compared to novice fencers. These elite features of neuromuscular coordination resulted in higher magnitudes of forward linear velocity of the body center of mass and weapon. Training should focus on explosive power. Sex- and equipment-specific effects could not be evaluated based on available research.
BackgroundWhile appropriate pillow height is crucial to maintaining the quality of sleep and overall health, there are no universal, evidence-based guidelines for pillow design or selection. We aimed to evaluate the effect of pillow height on cranio-cervical pressure and cervical spine alignment.MethodsTen healthy subjects (five males) aged 26 ± 3.6 years were recruited. The average height, weight, and neck length were 167 ± 9.3 cm, 59.6 ± 11.9 kg, and 12.9 ± 1.2 cm respectively. The subjects lay on pillows of four different heights (H0, 110 mm; H1, 130 mm; H2, 150 mm; and H3, 170 mm). The cranio-cervical pressure distribution over the pillow was recorded; the peak and average pressures for each pillow height were compared by one-way ANOVA with repeated measures. Cervical spine alignment was studied using a finite element model constructed based on data from the Visible Human Project. The coordinate of the center of each cervical vertebra were predicted for each pillow height. Three spine alignment parameters (cervical angle, lordosis distance and kyphosis distance) were identified.ResultsThe average cranial pressure at pillow height H3 was approximately 30% higher than that at H0, and significantly different from those at H1 and H2 (p < 0.05). The average cervical pressure at pillow height H0 was 65% lower than that at H3, and significantly different from those at H1 and H2 (p < 0.05). The peak cervical pressures at pillow heights H2 and H3 were significantly different from that at H0 (p < 0.05). With respect to cervical spine alignment, raising pillow height from H0 to H3 caused an increase of 66.4% and 25.1% in cervical angle and lordosis distance, respectively, and a reduction of 43.4% in kyphosis distance.DiscussionPillow height elevation significantly increased the average and peak pressures of the cranial and cervical regions, and increased the extension and lordosis of the cervical spine. The cranio-cervical pressures and cervical spine alignment were height-specific, and they were believed to reflect quality of sleep. Our results provide a quantitative and objective evaluation of the effect of pillow height on the biomechanics of the head-neck complex, and have application in pillow design and selection.
Physiological microenvironment engineering has shown great promise in combating a variety of diseases. Herein, we present the rational design of reinforced and injectable blood-derived protein hydrogels (PDA@SiO2-PRF) composed of platelet-rich fibrin (PRF), polydopamine (PDA), and SiO2 nanofibers that can act as dual-level regulators to engineer the microenvironment for personalized bone regeneration with high efficacy. From the biophysical level, PDA@SiO2-PRF with high stiffness can withstand the external loading and maintaining the space for bone regeneration in bone defects. Particularly, the reinforced structure of PDA@SiO2-PRF provides bone extracellular matrix (ECM)-like functions to stimulate osteoblast differentiation via Yes-associated protein (YAP) signaling pathway. From the biochemical level, the PDA component in PDA@SiO2-PRF hinders the fast degradation of PRF to release autologous growth factors in a sustained manner, providing sustained osteogenesis capacity. Overall, the present study offers a dual-level strategy for personalized bone regeneration by engineering the biophysiochemical microenvironment to realize enhanced osteogenesis efficacy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.