Background: In conjunction with an automated external defibrillator (AED) placement program at various locations within a public university in Malaysia, a series of structured training programs were conducted. The objectives of this study is to (1) evaluate the effectiveness of a structured training program in improving the perception of the importance of AED and cardiopulmonary resuscitation (CPR), (2) evaluate the confidence of the employees in using an AED and performing bystander CPR, (3) identify the fears and concerns of these employees in using AED and performing CPR, and (4) determine the perception of these employees towards the strategy of the AEDs placed at various locations within the university. Methods: In this single-center observational study, a validated questionnaire aimed to assess the university employees' attitude and confidence in handling AED and performing CPR before (pre-test) and immediately after (post-test) the training program was conducted. Results: A total of 184 participants participated in this study. Using the Wilcoxon signed-rank test, the training programs appeared to have improved the perception that "using AED is important for unresponsive victims" (z = 4.32, p < 0.001) and that "AED practice drills should be performed on a regular basis" (z = − 2.41, p = 0.02) as well as increased the confidence to perform CPR (z = − 8.56, p < 0.001), use AED (z = − 8.93, p < 0.001), identify victims with no signs of life (z = − 7.88, p < 0.001), and the willingness to perform CPR and AED without hesitancy (z = − 8.91, p < 0.001). Fears and concerns on performing CPR and using AED also appeared to have been significantly reduced, and the perception on placement strategies of these AEDs was generally positive.
ObjectivesThis paper describes the development and translation of a questionnaire purported to measure (1) the perception of the placement strategy of automated external defibrillator, (2) the perception on the importance of bystander cardiopulmonary resuscitation and automated external defibrillator (3) the perception on the confidence and willingness to apply these two lifesaving interventions as well as (4) the fears and concerns in applying these two interventions. For construct validation, exploratory factor analysis was performed using principal axis factoring and promax oblique rotation and confirmatory factor analysis performed using partial least square.ResultsFive factors with eigenvalue > 1 were identified. Pattern matrix analysis showed that all items were loaded into the factors with factor loading > 0.4. One item was subsequently removed as Cronbach’s alpha > 0.9 which indicates redundancy. Confirmatory factor analysis demonstrated acceptable factor loadings except for one item which was subsequently removed. Internal consistency and discriminant validity was deemed acceptable with no significant cross-loading.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.