Bullous pemphigoid is an inflammatory subepidermal blistering disease that is associated with auto- antibodies to the keratinocyte surface protein, BP180. In addition to the binding of autoantibodies, the infiltration of inflammatory cells is necessary for blister formation. Cytokines, including interleukin-6 and interleukin-8, have been implicated in the disease process of both human and experimental murine bullous pemphigoid. This study was aimed at testing the hypothesis that the binding of anti-BP180 antibodies to their target antigen triggers a signal transduction event that results in the secretion of these pro-inflammatory cytokines. Consistent with this hypothesis, treatment of cultured normal human epidermal keratinocytes with bullous pemphigoid IgG, but not control IgG, led to increased levels of interleukin-6 and interleukin-8, but not interleukin-1alpha, interleukin-1beta, tumor necrosis factor-alpha, interleukin-10, or monocyte chemoattractant protein-1, in the culture medium. This effect was concentration- and time-dependent and was abolished by depleting the bullous pemphigoid IgG of reactivity to two distinct epitopes on the BP180 NC16A domain. Upregulation of interleukin-6 and interleukin-8 was found at both protein and mRNA levels. In addition, bullous pemphigoid IgG did not induce the release of interleukin-6 and interleukin-8 from BP180-deficient keratinocytes obtained from a patient with generalized atrophic benign epidermolysis bullosa. These data indicate that bullous pemphigoid-associated autoantibodies to the human BP180 ectodomain trigger a signal transducing event that leads to expression and secretion of interleukin-6 and interleukin-8 from human keratinocytes.
The micronucleus assay (MNT) in human lymphocytes is frequently used to assess chromosomal damage as a consequence of environmental mutagen exposure, to assess the effect of mutagens or to search for reduced DNA repair capacity after a mutagenic challenge. We have established an automated scoring procedure for the cytokinesis blocked MNT based on computerized image analysis (Metasystems Metafer 4 version 2.12). To evaluate the results we used the reproducibility of counts, established a dose-response curve for gamma-irradiation and used the ability of the system to differentiate between breast cancer patients and controls as a biological reference, a difference which we had observed before by visual counting. Blood cultures were irradiated with gamma-rays (2 Gy) at the beginning and treated with cytochalasin B during the last 24 h. The slides were stained with Giemsa for visual counting and with DAPI for automated analysis. Our test sample consisted of 73 persons (27 with breast cancer and 26 female and 20 male controls). A comparison between visual counting (controls, mean MN frequency 313) and automated counting (mean MN frequency 106) in slides from the same culture revealed a large drop for the automated counts. However, the automated counts were as reproducible as the visual counts [coefficient of variation (CV) on the sample approximately 20%; CV on repeated counts of the same slides approximately 5%] and both counts were highly correlated. Furthermore, the discrimination between cases and controls improved for automated counting of slides from the same cultures [visual odds rato (OR) < or = 4.0, P = 0.009; automated OR > 16, P < 0.0001], with a strong dependence on the set of parameters used. This improvement was confirmed in a validation sample of an additional 21 controls and 20 cases (OR = 11, P = 0.0018) performed as a prospective or diagnostic test.
The micronucleus test in binucleated lymphocytes is a sensitive standard assay for biomonitoring, mutagenicity testing and to assess radiosensitivity of blood donors. The results vary between laboratories and scorers which led to the definition of international scoring criteria. We used these criteria in a case-control study, but nevertheless observed large differences between the seven scorers on the level of descriptive analysis. Therefore, we used the repeat measurements (267 in 98 blood donors) from this dataset (354 measurements in 185 blood donors) to analyse scoring variability in the setting of a case-control study. The variability was assessed by analysis of variance, which revealed the storage time of the blood samples, the blood donors including their disease status, and the scorers as sources of variation in the entire dataset. In addition, the coefficient of variation (CV) of the measurements was determined (overall: CV = 24.3%). After stepwise removal of biological and experimental variation by normalizations, the CV dropped to 6.8% on average, which may reflect the 'pure counting error'. The scorer-specific CVs were between 5.5 and 9.5%. The differences between the scorers suggested by the raw data were neither related to the scorer-specific CV nor to their experience. Instead, we observed a general decline of the micronuclei frequencies towards the end of the study for all scorers. This could not be related to a change in experimental conditions or in the defined scoring criteria. An explanation could be an unintended and unrecognized change of scoring criteria. Since the change in the results did not occur in automated counting we suggest to use either reference slides in longer-lasting studies or automated counting by image analysis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.