This study examines agreement between the devices Anterion® and Pentacam HR® used for corneal and pupil measurements in healthy eyes. The parameters compared between the two devices were: anterior Km (D), anterior K2 (D), anterior K1 (D), anterior K1 axis (°), anterior astigmatism (D), anterior K max (D), posterior Km (D), posterior K2 (D), posterior K1 (D), posterior K1 axis (°), posterior astigmatism (D), CCT (µm), thinnest point thickness (µm), thinnest point X-coordinate (mm), thinnest point Y-coordinate (mm), pupil diameter (mm), pupil center-corneal vertex distance (mm) (angle kappa), pupil centroid angle (°), pupil centroid X-coordinate (mm), and pupil centroid Y-coordinate (mm). The Student’s t test for independent samples identified significant differences (p < 0.005) between devices for the measurements anterior and posterior flat K axis, posterior flat K, steep K, and mean K. For these last three measurements, although significant, none of the differences were clinically relevant. Corneal power and thickness measurements except Kf axis showed excellent agreement between Anterion and Pentacam. In a clinical setting we would not recommend the interchangeable use of Pentacam and Anterion for measurement of pupil parameters.
Optical coherence tomography angiography (OCTA) enables three-dimensional, high-resolution, depth-resolved flow to be distinguished from non-vessel tissue signals in the retina. Thus, it enables the quantification of the 3D surface area of the retinal vessel signal. Despite the widespread use of OCTA, no representative spatially rendered reference vessel surface area data are published. In this study, the OCTA vessel surface areas in 203 eyes of 107 healthy participants were measured in the 3D domain. A Generalized Linear Model (GLM) model analysis was performed to investigate the effects of sex, age, spherical equivalent, axial length, and visual acuity on the OCTA vessel surface area. The mean overall vessel surface area was 54.53 mm2 (range from 27.03 to 88.7 mm2). OCTA vessel surface area was slightly negatively correlated with age. However, the GLM model analysis identified axial length as having the strongest effect on OCTA vessel surface area. No significant correlations were found for sex or between left and right eyes. This is the first study to characterize three-dimensional vascular parameters in a population based on OCTA with respect to the vessel surface area.
Perivascular epithelioid cell tumors (PEComas) are infrequent mesenchymal neoplasms that have particular histological and immunohistochemical features. Only a few cases have been described in the eye and orbit. This report presents a 28-year-old man who consulted for a painless left orbital mass. With the presumptive diagnosis of cavernous hemangioma, a surgical excisional biopsy was performed. Histopathological examination showed a well-delimited tumor composed of epithelioid cells with an eosinophilic cytoplasm and oval nucleus. The tumor cells stained diffusely for HMB-45 and transcription factor E3 (TFE3) and were focally positive for actin. There was no reactivity to S100 or desmin. Genetic testing revealed a TFE3 rearrangement. Based on these results, an extremely rare orbital TFE3-rearranged PEComa was diagnosed. Although no recurrence was seen at last follow-up, a review of the literature shows experience is limited regarding orbital PEComas and their malignant potential. Further research is needed to establish management guidelines, their association with the tuberous sclerosis complex, and the role of genetic mutations such as TFE3 rearrangement.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.