We aimed to evaluate the growth pattern and doubling time (DT) of pulmonary adenocarcinomas exhibiting ground-glass opacities (GGOs) on multidetector computed tomography (CT). METHODS The growth pattern and DT of 22 pulmonary adenocarcinomas exhibiting GGOs were retrospectively analyzed using three-dimensional semiautomatic software. Analysis of each lesion was based on calculations of volume and mass changes and their respective DTs throughout CT follow- up. Three-dimensional segmentation was performed by a single radiologist on each CT scan. The same observer and another radiologist independently repeated the segmentation at the baseline and the last CT scan to determine the variability of the measurements. The relationships among DTs, histopathology, and initial CT features of the lesions were also analyzed. RESULTS Pulmonary adenocarcinomas presenting as GGOs exhibited different growth patterns: some lesions grew rapidly and some grew slowly, whereas others alternated between periods of growth, stability, or shrinkage. A significant increase in volume and mass that exceeded the coefficient of repeatability of interobserver variability was observed in 72.7% and 84.2% of GGOs, respectively. The volume-DTs and mass-DTs were heterogeneous throughout the follow-up CT scan (range, -4293 to 21928 and -3113 to 17020 days, respectively), and their intra- and interobserver variabilities were moderately high. The volume-DTs and mass-DTs were not correlated with the initial CT features of GGOs; however, they were significantly shorter in invasive adenocarcinomas (P = 0.002 and P = 0.001, respectively). CONCLUSION Pulmonary adenocarcinomas exhibiting GGOs show heterogeneous growth patterns with a trend toward a progressive increase in size. DTs may be useful for predicting tumor aggressiveness
Persistent part-solid nodules (PSNs) with a solid component <6 mm usually represent minimally invasive adenocarcinomas and are significantly less aggressive than PSNs with a solid component ≥6 mm. However, not all PSNs with a small solid component behave in the same way: some nodules exhibit an indolent course, whereas others exhibit more aggressive behavior. Thus, predicting the future behavior of this subtype of PSN remains a complex and fascinating diagnostic challenge. The main purpose of this study was to apply open-source software to investigate which quantitative computed tomography (CT) features may be useful for predicting the behavior of a select group of PSNs. We retrospectively selected 50 patients with a single PSN with a solid component <6 mm and diameter <15 mm. Computerized analysis was performed using ImageJ software for each PSN and various quantitative features were calculated from the baseline CT images. The area, perimeter, mean Feret diameter, linear mass density, circularity and solidity were significantly related to nodule growth (p ≤ 0.031). Therefore, quantitative CT analysis was helpful for predicting the future behavior of a select group of PSNs with a solid component <6 mm and diameter <15 mm.
Malignant melanoma is an aggressive cancer with a high metastatic potential. Among the multiple sites of metastatic disease, the lung is one of the most frequently involved sites. Typically, pulmonary metastases from malignant melanoma occur as solid nodules. Rarely, pulmonary involvement in metastatic melanoma occurs as subsolid nodules.
The present article describes an unusual case of a patient with malignant melanoma that developed two synchronous pulmonary metastases with two different densities on CT images (one solid and the other subsolid) and different morphological patterns on histologic images. The radiologic-pathologic correlation of these two patterns of presentation was also reported.
In the British Thoracic Society guidelines for incidental pulmonary nodules, volumetric analysis has become the recommended method for growth assessment in solid indeterminate pulmonary nodules (SIPNs) <300 mm3. In these guidelines, two different volume doubling time (VDT) cut-offs, 400 and 600 days, were proposed to differentiate benign from malignant nodules. The present study aims to evaluate the performance of these VDT cut-offs in a group of SIPNs <300 mm3 which were incidentally detected in a routine clinical setting. During a 7-year period, we retrospectively selected 60 patients with a single SIPN <300 mm3. For each SIPN, the volume and VDT were calculated using semiautomatic software throughout the follow-up period, and the performance of the 400- and 600-day VDT cut-offs was compared. In the selected sample, there were 38 benign and 22 malignant nodules. In this group of nodules, the sensitivity, negative predictive value and accuracy of the 600-day VDT cut-off were higher than those of the 400-day VDT cut-off. Therefore, in the management of SIPNs <300 mm3 which were incidentally detected in a clinical setting, the 600-day VDT cut-off was better at differentiating benign from malignant nodules than the 400-day VDT cut-off, by reducing the number of false negatives.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.