Aims The ideal phenotype of patients with functional mitral regurgitation (FMR) who benefit most of transcatheter edge-to-edge repair (TEER) is still unclear. Some studies have suggested that patients with disproportionate FMR may have a better outcome. The purpose of this study is to evaluate the prognostic value of proportionate versus disproportionate FMR, in patients undergoing TEER with MitraClip system. Methods and Results The multicenter observational MITRA-CTV registry includes 200 patients with moderate-severe (3+) to severe (4+) FMR undergoing MitraClip, between March 2013 and June 2021, at three European institutions such as Magna Graecia University of Catanzaro, University of Turin (Italy) and University of Vigo (Spain). Patients were defined as having proportionate or disproportionate FMR if their EROA/LVEDV (left ventricular end diastolic volume) ratio was ≤ or > from the median value (0.15), respectively. The primary endpoint was the composite of death from all causes and rehospitalizations for HF, at 1-year follow-up. The secondary endpoint was composed of the individual components of the primary endpoint and cardiovascular death. Patients with disproportionate FMR had higher EROA (0.47±0.2 cm2 vs 0.27±0.1 cm2) and smaller ventricles (LVEDV: 207 ± ml vs 239 ± 83 ml) than those with proportionate FMR. Procedural success was achieved in 95% of patients. Notably, 30-day residual MR was comparable in patients with disproportionate versus proportionate FMR. There were 4 (2%) deaths during hospitalization, and the median hospital stay after the procedure was 9 days (IQR 7- 9 days). At Kaplan-Meier analysis, an EROA/LVEDV ratio both higher and lower than the median value (0.15) was not associated with an increased incidence of the primary endpoint of death and rehospitalization for HF (HR 1.17 CI 95%[0.72;1.90],p=0.50). The only independent predictors of clinical outcomes at 1 year were: the presence of CKD (HR 4.11 95% CI[1.73;9.75], p=0.0014) and a post TMVR hospital stay >10 days (HR 2.53 95% CI[1.24;5.18],p=0.0111). Conclusion In our study, there were no significant differences in outcome in patients with proportionate versus proportionate FMR undergoing TEER with Mitraclip system.
Background The implantable loop recorder (ILR) is a subcutaneous device used to diagnose heart rhythm disorders, allowing the detection of any arrhythmic episodes which are related to the onset of patient-reported symptoms. Although the importance of implantable cardiac monitors has been widely recognized, it is also true that due to their subcutaneous nature, they are inclined to detect false-positive episodes which generate several warnings requiring additional checks from the health care personnel. For this reason implanted cardiac devices monitoring has been recently implemented by the use of artificial intelligence (AI), which applies deep learning algorithms for speeding up the telemetry follow-up checks without affecting the accuracy. Considering the increased need of remote monitoring during pandemics, such achievement should reduce the overwork superimposed on healthcare providers, but to date it is not known to what extent this technology confers a quantitative gain. Our main purpose is to demonstrate how AI can enhance remote monitoring of patients with implantable cardiac monitors, reducing false positives and improving the accuracy of information received by cardiologist. Methods we included twenty-six patients who undergoing ILR implantation between May 2019 and April 2022. Mean age was 58 ± 28 years and there was a higher prevalence of male subjects (n = 20; 76,9%). Fifteen patients received ILR implemented by the use of AI, eleven patients received ILR with standard remote monitoring system. We did follow up from April 2022 to September 2022 with dedicated remote monitoring platforms. The main events detected by ILR were atrial fibrillation (AF), pauses > 3 sec, supraventricular and ventricular arrhythmias, patient's symptom. Results among AI-ILR a total of 25 events were recorded and 92% (n= 23) of these were correctly identified, meanwhile 4% (n= 1) event was considered as false positive. AI implementation showed a sensitivity of 93% (95% CI 0,7018 to 0,9966) and specificity of 90% (95% CI 0,5958 to 0,9949) Among the ILR not supported by AI a total of 26 events were registered, in 76,9% (n=20) of these there was a true correspondence between the event reported and the real event, while in 19,1% (n=5) there wasn't correspondence with a sensitivity of 91% (95% CI 0,6461 to 0,9957) and specificity of 64% (95% CI 0,3876 to 0,8366). Based on these data, AI improves the accuracy of diagnosis, reducing the incidence of false positives with an important saving time for health care providers. Conclusions with our analysis we support the hypothesis that AI algorithms can augment diagnostic capabilities and provides an important contribute to clinical decision-making. The implementation of ILR monitoring with AI is still at the beginning, but continuously further investigations will determine the real added value of these algorithm. The wider adoption of AI technology in cardiovascular medicine seems eventually inevitable in the digital world of 21st century healthcare.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.