Air pollution is a major health hazard. The traditional habits and unique ethnic fire culture in Hunan Tujia region result in the long-term exposure of residents, especially elderly people, to pollutants. In this study, we conducted field monitoring and assessment of indoor pollutants in the residential houses of Hunan Tujia families and subsequently visualised and simulated fire pollutants in representative residential houses by using fire-dynamic-simulator software. Pollutant-control strategies, using passive smoke collectors and resizing windows, were proposed and simulated for validation. The results revealed that passive smoke collectors reduced the pollutant concentration in the hall house by 43.96%. Furthermore, the optimal window size was 1500 mm × 1500 mm, and the most reasonable windowsill height of the firepit was 1800 mm. The results of the study can be used to improve the indoor air quality of Tujia dwellings and mitigate the adverse health effects of exposure to indoor air pollution without restricting ethnic beliefs and traditional customs.
This study uses behavioral observation, interviews, and questionnaire research to investigate the residential environment. It also evaluates the elderly in four representative ancient towns of Xiangxi, namely, Liye Ancient Town, Furong Ancient Town, Liexi Ancient Town, and Xichehe Ancient Town. It includes indoor air (CO2, PM2.5, PM10) and light intensity monitoring for the residential environment. The results showed that the elderly had a significant sense of frustration and loneliness. Of the elderyly, 70% believed the current living environment had an impact on healthy living, and 45% believed the safety and convenience of the living environment should be improved. More than 80% of the elderly were dissatisfied with their indoor acoustic environment, and more than 70% were dissatisfied with their home transportation. More than 85% of the elderly considered traditional wooden components and spaces to be the source of cultural identity. Furthermore, the average indoor PM2.5 concentration during the fire pit fire was 350–600 µg/m3, about 4.7–8 times the Chinese standard value. The average concentration of PM10 in all rooms was more than 400 µg/m3, approximately three times the Chinese standard value. Also, targeted environmental improvement strategies were proposed. The study results provided actual information to develop a systematic approach and a targeted design based on the needs to improve the residential environment of the elderly in ancient cities.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.