Background: Atelectasis is one of the most common respiratory complications in patients undergoing open abdominal surgery. Peripheral oxygen saturation (SpO 2 ) and forced vital capacity (FVC) are bedside indicators of postoperative respiratory dysfunction. The aim of this study was to describe the changes in lung aeration, using quantitative analysis of magnetic resonance imaging (MRI) and the diagnostic accuracy of SpO 2 and FVC to detect postoperative atelectasis. Methods: Post-hoc analysis of a randomized trial conducted at a University Hospital in Dresden, Germany. Patients undergoing pre-and postoperative lung MRI were included. MRI signal intensity was analyzed quantitatively to define poorly and nonaerated lung compartments. Postoperative atelectasis was defined as nonaerated lung volume above 2% of the total lung volume in the respective MRI investigation.Results: This study included 45 patients, 27 with and 18 patients without postoperative atelectasis. Patients with atelectasis had higher body mass index (p = .024), had more preoperative poorly aerated lung volume (p = .049), a lower preoperative SpO 2 (p = .009), and a lower preoperative FVC (p = .029). The amount of atelectasis correlated with preoperative SpO 2 (Spearman's ρ = À.51, p < .001) and postoperative SpO 2 (ρ = À.60, p < .001), and with preoperative FVC (ρ = À.29, p = .047) and postoperative FVC (ρ = À.40, p = .006). A postoperative SpO 2 ≤ 94% had 74% sensitivity and 78% specificity to detect atelectasis, while postoperative FVC ≤ 50% had 56% sensitivity and 100% specificity to detect atelectasis. Conclusion: SpO 2 and FVC correlated with the amount of postoperative non-aerated lung volume, showing acceptable diagnostic accuracy in bedside detection of postoperative atelectasis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.