ObjectiveThoracic outlet syndrome (TOS) should be considered of arterial origin only if patients have clinical symptoms that are the result of documented symptomatic ischemia. Simultaneous recording of inflow impairment and forearm ischemia in patients with suspected TOS has never been reported to date. We hypothesized that ischemia would occur in cases of severely impaired inflow, resulting in a non-linear relationship between changes in pulse amplitude (PA) and the estimation of ischemia during provocative attitudinal upper limb positioning.DesignProspective single center interventional study.MaterialFifty-five patients with suspected thoracic outlet syndrome.MethodsWe measured the minimal decrease from rest of transcutaneous oximetry pressure (DROPm) as an estimation of oxygen deficit and arterial pulse photo-plethysmography to measure pulse amplitude changes from rest (PA-change) on both arms during the candlestick phase of a “Ca + Pra” maneuver. “Ca + Pra” is a modified Roos test allowing the estimation of maximal PA-change during the “Pra” phase. We compared the DROPm values between deciles of PA-changes with ANOVA. We then analyzed the relationship between mean PA-change and mean DROPm of each decile with linear and second-degree polynomial (non-linear) models. Results are reported as median [25/75 centiles]. Statistical significance was p < 0.05.ResultsDROPm values ranged −11.5 [−22.9/−7.2] and − 12.3 [−23.3/−7.4] mmHg and PA-change ranged 36.4 [4.6/63.8]% and 38.4 [−2.0/62.1]% in the right and left forearms, respectively. The coefficient of determination between median DROPm and median PA-change was r2 = 0.922 with a second-degree polynomial fitting, but only r2 = 0.847 with a linear approach.ConclusionOxygen availability was decreased in cases of severe but not moderate attitudinal inflow impairments. Undertaking simultaneous A-PPG and forearm oximetry during the “Ca + Pra” maneuver is an interesting approach for providing objective proof of ischemia in patients with symptoms of TOS suspected of arterial origin.
Only few studies have analyzed the associations of lower extremity artery disease (LEAD) with lumbar spinal stenosis (LSS), although it is expected to be a frequent association. With exercise-oximetry, we determined the presence of exercise-induced regional blood flow impairment (ischemia) in 5197 different patients complaining of claudication and referred for treadmill testing. We recorded height, weight, age, sex, ongoing treatments, cardiovascular risk factor (diabetes, high blood pressure, current smoking habit), and history of suspected or treated LSS and/or lower limb revascularization. An ankle-brachial index at rest < 0.90 or >1.40 on at least one side was considered indicative of the presence of LEAD (ABI+). Ischemia was defined as a minimal DROP (Limb-changes minus chest-changes from rest) value < –15 mmHg during exercise oximetry. We analyzed the clinical factors associated to the presence of exercise-induced ischemia in patients without a history of LSS, using step-by-step linear regression, and defined a score from these factors. This score was then tested in patients with a history of LSS. In 4690 patients without a history of (suspected, diagnosed, or treated) LSS, we observed that ABI+, male sex, antiplatelet treatment, BMI< 26.5 kg//m2, age ≤ 64 years old, and a history of lower limb arterial revascularization, were associated to the presence of ischemia. The value of the score derived from these factors was associated with the probability of exercise-induced ischemia in the 507 patients with a history of LSS. This score may help to suspect the presence of ischemia as a factor of walking impairment in patients with a history of lumbar spinal stenosis.
BackgroundVenous compression is the second most frequent form of thoracic outlet syndrome (TOS). Although venous photo-plethysmography (PPG) has been largely used to estimate the consequences of chronic thromboses (Paget Schroetter syndrome), systematic direct quantitative recording of hemodynamic consequences of positional venous outflow impairment in patients with suspected TOS has never been reported.ObjectiveWe hypothesized that moving the arms forward (prayer: “Pra” position) while keeping the hands elevated after a surrender/candlestick position (Ca) would allow quantification of 100% upper limb venous emptying (PPGmax) and quantitative evaluation of the emptying observed at the end of the preceding abduction period (End-Ca-PPG), expressed in %PPGmax.Materials and methodsWe measured V-PPG in 424 patients referred for suspected TOS (age 40.9 years old, 68.3% females) and retrieved the results of ultrasound investigation at the venous level. We used receiver operating characteristics curves (ROC) to determine the optimal V-PPG values to be used to predict the presence of a venous compression on ultrasound imaging. Results are reported as a median (25/75 centiles). Statistical significance was based on a two-tailed p < 0.05.ResultsAn End-Ca-PPG value of 87% PPGmax at the end of the “Ca” period is the optimal point to detect an ultrasound-confirmed positional venous compression (area under ROC: 0.589 ± 0.024; p < 0.001). This threshold results in 60.9% sensitivity, 47.6% specificity, 27.3% positive predictive value, 79.0% negative predictive value, and 50.8% overall accuracy.ConclusionV-PPG is not aimed at detecting the presence of a venous compression due to collateral veins potentially normalizing outflow despite subclavicular vein compression during abduction, but we believe that it could be used to strengthen the responsibility of venous compression in upper limb symptoms in TOS-suspected patients, with the possibility of non-invasive, bilateral, recordable measurements of forearm volume that become quantitative with the Ca-Pra maneuver.Clinical trial registration[ClinicalTrials.gov], identifier [NCT04376177].
Context: Thoracic outlet syndrome (TOS) is common among athletes and should be considered as being of arterial origin only if patients have “clinical symptoms due to documented symptomatic ischemia.” We previously reported that upper limb ischemia can be documented with DROPm (minimal value of limb changes minus chest changes) from transcutaneous oximetry (TcpO2) in TOS.Purpose: We aimed to test the hypothesised that forearm (F-) DROPm would better detect symptoms associated with arterial compression during abduction than upper arm (U-) DROPm, and that the thresholds would differ.Methods: We studied 175 patients (retrospective analysis of a cross-sectional acquired database) with simultaneous F-TcpO2 and U-TcpO2 recordings on both upper limbs, and considered tests to be positive (CS+) when upper limb symptoms were associated with ipsilateral arterial compression on either ultrasound or angiography. We determined the threshold and diagnostic performance with a receiver operating characteristic (ROC) curve analysis and calculation of the area under the ROC curve (AUROC) for absolute resting TcpO2 and DROPm values to detect CS+. For all tests, a two-tailed p < 0.05 was considered indicative of statistical significance.Results: In the 350 upper-limbs, while resting U-TcpO2 and resting F-TcpO2 were not predictive of CS + results, the AUROCs were 0.68 ± 0.03 vs. 0.69 ± 0.03 (both p < 0.01), with the thresholds being −7.5 vs. −14.5 mmHg for the detection of CS + results for U-DROPm vs. F-DROPm respectively.Conclusion: In patients with suspected TOS, TcpO2 can be used for detecting upper limb arterial compression and/or symptoms during arm abduction, provided that different thresholds are used for U-DROPm and F-DROPm.Clinical Trial Registration:ClinicalTrials.gov, identifier NCT04376177.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.