The mulberry plant (Morus alba L.) contains abundant anthocyanins (ANCs), which are natural antioxidants. The aim of this study was to determine the ANC composition of Thai Morus alba L. fruits and to assess the effect of an ANC extract on blood glucose and insulin levels in male leptin receptor-deficient Zucker diabetic fatty (ZDF) rats. The major components of the ANC extract were identified by high-performance liquid chromatography-electrospray ionization-mass spectrometry. ZDF and lean rats were treated with 125 or 250 mg ANCs/kg body weight, or 1% carboxymethylcellulose (CMC) twice daily for 5 weeks. Neither ANC dose had an effect on body weight. Following 5 weeks of treatment, glucose levels were observed to increase from 105.5±8.7 to 396.25±21 mg/dl (P<0.0001) in the CMC-treated ZDF rats; however, the glucose levels were significantly lower in the rats treated with 125 or 250 mg/kg ANCs (228.25±45 and 131.75±10 mg/dl, respectively; P<0.001 versus CMC). The administration of 250 mg/kg ANCs normalized glucose levels in the ZDF rats towards those of the lean littermates. Insulin levels were decreased significantly in the ZDF rats treated with CMC or 125 mg/kg ANCs (P<0.0001), but not in the rats treated with 250 mg/kg ANCs. Histologically, 250 mg/kg ANCs was observed to prevent islet degeneration compared with the islets in CMC-treated rats. This study, demonstrated that ANCs extracted from Morus alba L. were well tolerated and exhibited effective anti-diabetic properties in ZDF rats. ANCs represent a promising class of therapeutic compounds that may be useful in the prevention of type 2 diabetes.
Background/purposeResonance frequency analysis (RFA) is clinically used in dentistry to access the stiffness of dental implants in surrounding bone. However, the clear advantages and disadvantages of this method are still inconclusive. The aim of this study was to investigate and compare implant stability quotient (ISQ) values obtained from RFA with parameters obtained from a cone beam computed tomography (CBCT) scan of the same region.Materials and methodsNineteen implants (Conelog) were inserted in the posterior maxillary and mandibular partially edentulous regions of 16 patients. At the time of implant placement, the ISQ values were obtained using RFA (Osstell). CBCT was used to measure the thickness of the crestal, cortical, buccolingual cortical, and cancellous bone at 3, 6, and 9 mm below the crestal bone level, as indicated by radiographic markers. The ratio of the thickness of the cortical to cancellous bone at varying depths was also calculated and classified into 4 groups (Group 1–4).ResultsThere was a strong correlation between the crestal cortical bone thickness and ISQ values (P<0.001). The thickness of the buccolingual cortical bone and ratio of the cortical to cancellous bone thickness at 3 mm were significantly related to the ISQ (P = 0.018 and P = 0.034, respectively). Furthermore, the ISQs in Group 1 were the highest compared with those in Group 2 and Group 3, whereas the CBCT parameters at 6 and 9 mm did not have any specific correlation with the ISQ values.ConclusionThis study showed that the ISQ values obtained from RFA highly correlated with the quantity and quality of bone 3 mm below the crestal bone level. The correlation between the ISQ and bone surrounding the implant site was dependent on the depth of measurement. Therefore, RFA can help to predict the marginal bone level, as confirmed in this study.
This clinical report presents the prosthetic rehabilitation of a congenital auricular defect. The rehabilitation was initially performed with an adhesive retained silicone prosthesis. After careful evaluation of the patient's retentive needs, two endo-osseous craniofacial implants were placed in the mastoid region. After integration, an implant-retained silicone prosthesis was fabricated using a Hader bar with two ERA attachments, which restored the defect with good aesthetic and functional outcome. Prosthetic rehabilitation is a viable treatment option for restoring auricular defects and can be indicated in situations where surgical reconstruction may not be feasible.
Orbital defect, arising from tumor-related resections, trauma, and congenital anomalies, can lead to negative functional and psychological effects in the patients. Rehabilitation with an orbital prosthesis can provide satisfactory aesthetic outlook and can be combined with surgical reconstruction to improve the retention. Despite less than ideal properties, silicone elastomer is the most commonly used material to fabricate orbital prosthesis. Several studies have been conducted on developing newer materials and improving the properties of silicone elastomer. Craniofacial implants offer greater retention compared to adhesives, but they have been observed to have a higher risk of implant failure and related side effects when placed in irradiated bone. This review gives a scope on understanding the current challenges faced during fabrication of orbital prosthesis and the future directions of this field.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.