BackgroundWrist-worn monitors claim to provide accurate measures of heart rate and energy expenditure. People wishing to lose weight use these devices to monitor energy balance, however the accuracy of these devices to measure such parameters has not been established.AimTo determine the accuracy of four wrist-worn devices (Apple Watch, Fitbit Charge HR, Samsung Gear S and Mio Alpha) to measure heart rate and energy expenditure at rest and during exercise.MethodsTwenty-two healthy volunteers (50% female; aged 24 ± 5.6 years) completed ~1-hr protocols involving supine and seated rest, walking and running on a treadmill and cycling on an ergometer. Data from the devices collected during the protocol were compared with reference methods: electrocardiography (heart rate) and indirect calorimetry (energy expenditure).ResultsNone of the devices performed significantly better overall, however heart rate was consistently more accurate than energy expenditure across all four devices. Correlations between the devices and reference methods were moderate to strong for heart rate (0.67–0.95 [0.35 to 0.98]) and weak to strong for energy expenditure (0.16–0.86 [-0.25 to 0.95]). All devices underestimated both outcomes compared to reference methods. The percentage error for heart rate was small across the devices (range: 1–9%) but greater for energy expenditure (9–43%). Similarly, limits of agreement were considerably narrower for heart rate (ranging from -27.3 to 13.1 bpm) than energy expenditure (ranging from -266.7 to 65.7 kcals) across devices.ConclusionThese devices accurately measure heart rate. However, estimates of energy expenditure are poor and would have implications for people using these devices for weight loss.
High-intensity interval training (HIIT) is recognized as a potent stimulus for improving cardiorespiratory fitness (volume of oxygen consumption [VO 2 ] peak) in patients with coronary artery disease (CAD). However, the feasibility, safety, and long-term effects of HIIT in this population are unclear. OBJECTIVE To compare HIIT with moderate-intensity continuous training (MICT) for feasibility, safety, adherence, and efficacy of improving VO 2 peak in patients with CAD. DESIGN, SETTING, AND PARTICIPANTS In this single-center randomized clinical trial, participants underwent 4 weeks of supervised training in a private hospital cardiac rehabilitation program, with subsequent home-based training and follow-up over 12 months.A total of 96 participants with angiographically proven CAD aged 18 to 80 years were enrolled, and 93 participants were medically cleared for participation following a cardiopulmonary exercise test.
The Sedentary Sphere enables determination of the most likely posture from the wrist-worn GENEActiv. Visualizing behaviors on the sphere displays the pattern of wrist movement and positions within that behavior.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.