This study was an investigation of the need for pre-treatment of a new raw water source for artificial groundwater recharge. The study was done through a column test, well sampling and survey data relating to 11 artificial recharge plants in Sweden. The column test showed that only 30% of the natural organic matter (NOM) was removed from the new raw water source during infiltration. The survey revealed that the new water source's quality was within the range requiring pre-treatment prior to infiltration. The well sampling results showed a significant correlation between the NOM-content in the raw and treated waters for WTPs without pre-treatment (r = 0.78 and ρ = 0.04), indicating one of the short-term limitations of artificial recharge. The study results indicate that the new raw water source is unsuitable for direct use in artificial recharge and that treatment is required prior to infiltration.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.