For evaluation of perianal fistulas, hydrogen peroxide-enhanced three-dimensional endoanal ultrasonography and endoanal magnetic resonance imaging have good agreement, especially for classification of the primary fistula tract and the location of an internal opening. These results also show good agreement compared with surgical findings. Therefore, hydrogen peroxide-enhanced three-dimensional endoanal ultrasonography and endoanal magnetic resonance imaging can both be used as reliable methods for preoperative evaluation of perianal fistulas.
Purpose:To optimize and assess the feasibility of a singleshot black-blood T2-weighted spin-echo echo-planar imaging (SSBB-EPI) sequence for MRI of the liver using sensitivity encoding (SENSE), and compare the results with those obtained with a T2-weighted turbo spin-echo (TSE) sequence.
Materials and Methods:Six volunteers and 16 patients were scanned at 1.5T (Philips Intera). In the volunteer study, we optimized the SSBB-EPI sequence by interactively changing the parameters (i.e., the resolution, echo time (TE), diffusion weighting with low b-values, and polarity of the phaseencoding gradient) with regard to distortion, suppression of the blood signal, and sensitivity to motion. The influence of each change was assessed. The optimized SSBB-EPI sequence was applied in patients (N ϭ 16). A number of items, including the overall image quality (on a scale of 1-5), were used for graded evaluation. In addition, the signal-to-noise ratio (SNR) of the liver was calculated. Statistical analysis was carried out with the use of Wilcoxon's signed rank test for comparison of the SSBB-EPI and TSE sequences, with P ϭ 0.05 considered the limit for significance.
Results:The SSBB-EPI sequence was improved by the following steps: 1) less frequency points than phase-encoding steps, 2) a b-factor of 20, and 3) a reversed polarity of the phase-encoding gradient. In patients, the mean overall image quality score for the optimized SSBB-EPI (3.5 (range: 1-4)) and TSE (3.6 (range: 3-4)), and the SNR of the liver on SSBB-EPI (mean Ϯ SD ϭ 7.6 Ϯ 4.0) and TSE (8.9 Ϯ 4.6) were not significantly different (P Ͼ .05).
Conclusion:Optimized SSBB-EPI with SENSE proved to be feasible in patients, and the overall image quality and SNR of the liver were comparable to those achieved with the standard respiratory-triggered T2-weighted TSE sequence.
3D HPUS and endoanal MRI are equally adequate for the evaluation of perianal fistulas. Both methods are associated with similar discomfort and patients have no preference for either procedure.
Three-dimensional EUS and endoanal MRI are comparable for detecting EAS defects. However, correlation between the two methods for EAS thickness, length and area is poor. This is also the case for EAS volume determined on 3D EUS and EAS thickness and area measured on endoanal MRI. Three-dimensional EUS can be used for detecting EAS defects, but no 3D EUS measurements are suitable parameters for assessing EAS atrophy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.