This study aimed at presenting the intra-tester reliability of the static load bearing exercises (LBEs) performed by individuals with transfemoral amputation (TFA) fitted with an osseointegrated implant to stimulate the bone remodeling process. There is a need for a better understanding of the implementation of these exercises particularly the reliability. The intra-tester reliability is discussed with a particular emphasis on inter-load prescribed, inter-axis and inter-component reliabilities as well as the effect of body weight normalization. Eleven unilateral TFAs fitted with an OPRA implant performed five trials in four loading conditions. The forces and moments on the three axes of the implant were measured directly with an instrumented pylon including a six-channel transducer. Reliability of loading variables was assessed using intraclass correlation coefficients (ICCs) and percentage standard error of measurement values ( %SEMs ). The ICCs of all variables were above 0.9 and the %SEM values ranged between 0 and 87%. This study showed a high between-participants' variance highlighting the lack of loading consistency typical of symptomatic population as well as a high reliability between the loading sessions indicating a plausible correct repetition of the LBE by the participants. However, these outcomes must be understood within the framework of the proposed experimental protocol.
The significant lack of axial compliance led to systematic underloading of the long axis of the implant. Clinical relevance This study contributes to a better understanding of the load applied on an osseointegrated implant during the static load-bearing exercises that could contribute to improve the design of apparatus to monitor loading exercises as well as clinical guidelines for the loading progression during rehabilitation.
The primary objective of this scoping review is to characterize rehabilitation programs for individuals with transfemoral amputation following the implantation of screw-type or press-fit osseointegrated fixations for bone-anchored prostheses.The secondary objective of this review is to describe partial weight bearing exercises including static and dynamic exercises as well as use of walking aids in each rehabilitation program for screw-type and press-fit fixations.The third objective of this review is to compare key rehabilitation parameters for various partial weight bearing exercises (e.g. type of training prosthesis, loading time and progression, monitoring of loading, loading direction, instructions given to patients and the use of loading regulators) within each program for screw-type and press-fit fixations (intra-variability) and between programs for screw-type and press-fit fixations (inter-variability).The specific review questions are.
Objectives To synthesize the evidence on the psychometrics functional capacity evaluation (FCE) methods. Methods A systematic literature search in nine databases. The resulting articles were screened based on predefined in- and exclusion criteria. Two reviewers independently performed this screening. Included studies were appraised based on their methodological quality. Results The search resulted in 20 eligible studies about nine different FCE methods. The Baltimore Therapeutic Equipment work simulator showed a moderate predictive validity. The Ergo-Kit (EK) showed moderate variability and high inter- and intra-rater reliability. Low discriminative abilities and high convergent validity were found for the EK. Concurrent validity of the EK and the ERGOS Work Simulator was low to moderate. Moderate to high test-retest, inter- and intra-reliability was found in the Isernhagen Work-Systems (IWS) FCE. The predictive validity of the IWS was low. The physical work performance evaluation (PWPE) showed moderate test-retest reliability and moderate to high inter-rater reliability. Low internal and external responsiveness were found for the PWPE, predictive validity was high. The predictive validity of the short-form FCE was also high but need to be further examined on several psychometric properties. Low discriminative and convergent validity were found for the work disability functional assessment battery. The WorkHab showed moderate to high test-retest, inter- and intra-rater reliability. Conclusion Well-known FCE methods have been rigorously studied, but some of the research indicates weaknesses in their reliability and validity. Future research should address how these weaknesses can be overcome.
The main purpose of this scoping review is to characterize loading information applied on the residuum of individuals with transfemoral amputation fitted with an osseointegrated fixation for bone-anchored prostheses.The objectives of this scoping review are: i) to map the scope of loading variables, and ii) to report the range of magnitude of loads that has been directly measured using a portable kinetic recording apparatus fitted at the distal end of the residuum during rehabilitation exercises, standardized and unscripted activities of daily living, and adverse events.The specific review questions are.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.