Association between Hydroxychloroquine (HCQ) and Azithromycin (AZT) is under evaluation for patients with lower respiratory tract infection (LRTI) caused by the Severe Acute Respiratory Syndrome (SARS-CoV-2). Both drugs have a known torsadogenic potential, but sparse data are available concerning QT prolongation induced by this association. Our objective was to assess for COVID-19 LRTI variations of QT interval under HCQ/AZT in patients hospitalized, and to compare manual versus automated QT measurements. Before therapy initiation, a baseline 12 lead-ECG was electronically sent to our cardiology department for automated and manual QT analysis (Bazett and Fridericia's correction), repeated 2 days after initiation. According to our institutional protocol (Pasteur University Hospital), HCQ/ AZT was initiated only if baseline QTc ≤ 480ms and potassium level> 4.0 mmol/L. From March 24 th to April 20 th 2020, 73 patients were included (mean age 62 ± 14 years, male 67%). Two patients out of 73 (2.7%) were not eligible for drug initiation (QTc ≥ 500 ms). Baseline average automated QTc was 415 ± 29 ms and lengthened to 438 ± 40 ms after 48 hours of combined therapy. The treatment had to be stopped because of significant QTc prolongation in two out of 71 patients (2.8%). No drug-induced life-threatening arrhythmia, nor death was observed. Automated QTc measurements revealed accurate in comparison with manual QTc measurements. In this specific population of inpatients with COVID-19 LRTI, HCQ/AZT could not be initiated or had to be interrupted in less than 6% of the cases.
Successful catheter ablation of scar-related atrial tachycardia depends on correct identification of the critical isthmus. Often, this is a represented by a small bundle of viable conducting tissue within a low-voltage area. It's identification depends on the magnitude of the signal/ noise ratio. Ultra-high density mapping, multipolar catheters with small (eventually unidirectional) and closely-spaced electrodes improves low-voltage electrogram detection. Background noise limitation is also of major importance for improving the signal/noise ratio. Electrophysiological properties of the critical isthmus and the characteristics of the local bipolar electrograms have been recently demonstrated as hallmarks of successful ablation sites in the setting of scar-related atrial tachycardia.
Background:
Tetralogy of Fallot (TOF) is the most common cyanotic congenital heart disease, and sudden cardiac death represents an important mode of death in these patients. Data evaluating the implantable cardioverter defibrillator (ICD) in this patient population remain scarce.
Methods:
Nationwide French Registry including all TOF patients with an ICD initiated in 2010 by the French Institute of Health and Medical Research. The primary time to event endpoint was the time from ICD implantation to first appropriate ICD therapy. Secondary outcomes included ICD-related complications, heart transplantation, and death. Clinical events were centrally adjudicated by a blinded committee.
Results:
A total of 165 patients (mean age 42.2±13.3 years, 70.1% males) were included from 40 centers, including 104 (63.0%) in secondary prevention. During a median (IQR) follow-up of 6.8 (2.5-11.4) years, 78 (47.3%) patients received at least one appropriate ICD therapy. The annual incidence of the primary outcome was 10.5% (7.1% and 12.5% in primary and secondary prevention, respectively, p=0.03). Overall, 71 (43.0%) patients presented with at least one ICD complication, including inappropriate shocks in 42 (25.5%) patients and lead dysfunction in 36 (21.8%) patients. Among 61 (37.0%) primary prevention patients, the annual rate of appropriate ICD therapies was 4.1%, 5.3%, 9.5%, and 13.3% in patients with respectively no, one, two, or ≥ three guideline-recommended risk factors. QRS fragmentation was the only independent predictor of appropriate ICD therapies (HR 3.47, 95% CI 1.19-10.11), and its integration in a model with current criteria increased the 5-year time-dependent area under the curve from 0.68 to 0.81 (p=0.006). Patients with congestive heart failure and/or reduced LVEF had a higher risk of non-arrhythmic death or heart transplantation (HR=11.01, 95% CI: 2.96-40.95).
Conclusions:
Patients with TOF and an ICD experience high rates of appropriate therapies, including those implanted in primary prevention. The considerable long-term burden of ICD-related complications, however, underlines the need for careful candidate selection. A combination of easy-to-use criteria including QRS fragmentation might improve risk stratification.
Clinical Trial Registration:
URL: https://clinicaltrials.gov Unique Identifier: NCT03837574
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.