The objective of this research is to study and compare quality milling surfaces, and the effects of plastic mould steels AISI-1050 and AISI-P20, in a milling process with various parameters based on experimental conditions, such as: 1) feed rates at 45, 50 and 55 mm/min, 2) spindle speeds of 510, 572 and 637 rpm, and 3) milling levels at 3, 5, and 10 mm, respectively, using a 10 mm twin flute ended type mill. The experimental results found that plastic mould steels which had the best quality milling surface were AISI-P20 and AISI-1050, with roughnesses of 2.627 μm and 2.120 μm, respectively. Quality milling surfaces were milled by using the most suitable parameter feed rate of 45 mm/min, a spindle speed of 637 rpm and a cut depth level of 3 mm, for both tested grades. However, characteristics of milling surfaces and wear of the mill end were directly influenced by changes of parameters for all test conditions. As a result, the quality of milling surfaces also changed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.